Super Anleitung. Ordentliche Auflösung. Das ganze noch in Deutsch wäre zu schön. Alle Datenblätter sind sauber Kopiert und alle Leitungswege sind sauber ausgeführt
Thanks God for the internet and thanks for the service like this - proffessional solution on time.
Text excerpt from page 12 (click to view)
14GT15 14GT20
PURITY ADJUSTMENT
No. Adjusting point 1 PURITY ADJ. Adjusting procedure/conditions 1. Receive the GREEN-ONLY signal. Adjust the beam current to about 500 µA. 2. Maintain the purity magnet at the zero magnetic field and keep the static convergence roughly adjusted. 3. Observe the points a, b as shown in Fig. 4-1 through the microscope. Adjust the landing to the A rank requirements. 4. Orient the raster rotation to 0 eastward. 5. Tighten up the deflection coil screws. » Tightening torque: 108 ± 20 N (11 ± 2 kgf) 6. Make sure the CRT corners landing meet the A rank requirements. If not, stick the magnet sheet to correct it. Note: This adjustment must be done after warming up the unit for 30 minutes or longer with a beam current over 500 µA. Waveform and others