PRODUCT DESCRIPTION SHEET
CONTROL PANEL
1. 2. 3. 4. Control panel Grease filters Lighting unit Telescopic flue A. Light switch. B. Speed selector switch.
A
small amount of steam and fumes medium amount of steam and fumes
B
large amount of steam and fumes
Removing and washing the grease filters - Fig. 1
1. Unplug the appliance or disconnect the mains power supply. 2. Remove the grease filters: a - push the handles backwards b - and then downwards. 3. After cleaning the grease filter refit in reverse order, making sure the entire extraction surface is covered.
Fitting or renewing the carbon filter Fig. 2
1. Unplug the appliance or disconnect the mains power supply. 2. Remove the grease filters. 3. If the carbon filters are already mounted (two filters covering the motor protection grille) and need renewing, turn the central handle anticlockwise until the filters release. 4. If the filters are not already fitted locate one on each side to cover both motor protection grilles, then turn the central handle of the filters clockwise. 5. Replace the grease filters.
Fig. 1
Fig. 2
Replacing bulbs - Fig. 3
1. Unplug the appliance or disconnect the mains power supply. 2. Remove the grease filters. 3. Remove the lighting unit from the clips that fix it to the hood body. 4. Remove the burnt-out bulb. Replace using 40W max (E14) bulbs only. 5. Refit the lighting unit and the grease filters.
Fig. 3
5019 100 75201