It's great to be able to obtain a precious technical information for a real old equipment. The one I got helps me a lot in the area of wiring diagram to repair my antique. PDF gave me clear enough information to find out thr details. Thanks for giving me the oppotunity to be able to access to almost vanished informations.
 ;
Another excellent aquisition. Fine detailed manual. Thanks
 ;
Good quality for the scan, complete, but as usual for Tascam, not so comprehensive !
32PD5000/42PD5000/37PD5200 (PW1)
Item Vs and Va VOLTAGE ADJUSTMENT 32PD5000, 37PD5000, 37PD5000 Procedure (1) If the difference between the printed voltage of Vs and the indicated value of Vs Voltmeter is over 0.1V, adjust the Vs ADJ VR located upward on the Power Supply Unit to make it within 0.1V. (2) If the difference between the printed voltage of Va and the indicated value of Va Voltmeter is over 0.2V, adjust the Va ADJ VR located upward on the Power Supply Unit to make it within 0.2V. (3) Check and do the procedure (1) again. <Example of the Voltage Label>
<LOT> ************** Vs= 80.0V Va=60.0V Vw=140.0V Vx=60.0V
Applicable Model
Preparation (1) Keep heat-run for 1 minutes or more.
(2) Connect the DC Voltmeter to the Vs test point and the GND point (or the Va test point and the GND point) on the Power Supply Unit. (3) Receive the all black signal with no setup. (4) Check the indication of Vs and Va voltages printed on the label located upper right side on the Panel Module.
Label
Y-sus
Power Supply Unit
X-sus
MPF7409 S/N ********* * MADE IN JAPAN
Panel Module
(Rear View)
Va ADJ Va
Vs ADJ
GND
Power Supply Unit
Vs
25
|