42PD7500 (PW2)
Power
Power cannot be turned on (LED does not light)
Is the input voltage applied to Power supply unit? (CN61 ,) Yes
No
AC inlet
Power switch
AC Fuse F902 T6.3AH 250V
Filter PWB
Are the voltages applied to CN63 pins and CNPPS pins of Power supply unit ? Yes Joint / Formatter PWB
No [CN63] +5V [CNPPS] +30V + 5V +12V +10V
Power supply unit *Re-adjustment is reqired. Plese refer to 22 page.