Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Sweet! I won the item on eBay and couldn't adjust the geometry or even keep a steady picure. This guide has the full schematics (not available anywhere else as far as I could tell), and was a bargain for the wealth of knowledge it contains. I hooked it up to my testing equipment, tweaked a few potentiometers and got it playing videogames in no time. Thanks!
 ;
It was just what I need to fix my old BMW's CD player. Very convenient also. Thank you.
 ;
Great Manual! It contains all the wiring schematics and mechanical exploded views that are essential for service and repair. I was surprised I even found this for such an old machine. Only wish I knew of this site many years ago.
 ;
Great manual very clear copied. You are making an incredible job. I appreciate a lot the rapidity and your efficiency. Thanks a lot
 ;
Good pdf of the service manual for this unit. Includes disassembly instructions, full schematics, board layouts, parts lists and diagnostic information. Some information is in the pdf twice (single pages, and split pages), but that could be how it was originally generated by panasonic, or perhaps the idea is to make it eaiser to put onto 8.5 x 11" pages.
Information was exactly what I needed. Delivery was overnight (less than 12 hours) and I was happy with the process.
Note:
Connect a probe (10: 1) of the oscilloscope test point for adjustment. Connect ground ( ) terminal of oscilloscope probe to TP3 (VREF) for all adjustment.
2. Tracking Balance Check
Oscilloscope (DC range)
1. Focus Bias Adjustment Make the focus bias adjustment when replacing and repairing the optical block.
Oscilloscope (DC range)
TP1 (TE) TP3 (VREF)
+ �
TP2 (RF) TP3 (VREF)
+ �
1) Connect an oscilloscope to test points TP1 (TE) and TP3 (VREF). 2) Start up the CD test mode. 3) Insert the test disc TCD-782 (YEDS-18) and enter the traverse mode of the CD test mode. 4) Confirm that the traverse waveform on an oscilloscope is vertically symmetrical as shown in the figure below. 5) After confirming the waveform, release the CD test mode.
1) Connect an oscilloscope to test points TP2 (RF) and TP3 (VREF). 2) Turn on the power switch. 3) Insert test disc TCD-782 (YEDS-18) and play back the second program. 4) Adjust SFR101 so that RF signal of the test point TP2 (RF) is MAX and CLEARREST.
A VREF B A=B
MAX 1.4 ± 0.1 Vp-p 0V EYE PATTERN must be CLEAR and MAX
VOLT/DIV: 20mV TIME/DIV: 1mS
VOLT/DIV: 0.5V TIME/DIV: 0.5µS Note: The current of the laser signal can be checked with the voltages on both sides of R46 (voltage across 10�). The difference for the specified value shown on the label must be within ± 6.0mA.
KSS-213B 15165 SG442
44.2mA
Laser current Iop =
Voltage across R46 10�
20
|
|
 |
> |
|