This scanned manual is well done in that most all the pages except for one is straight and clear- the way I would do them. One page was upside down but that happens. For the money that is charged on this site you get a pretty good deal. Now with complex repairs, I still prefer to us paper manuals which I have to buy at stereomanuals but the one I got here was much less than the $45 he was charging but this is a larger than normal manual for three different units. I am a picky manual user because I have used original manuals from Sony and Teac.
;
Very useful service manual, was exactly what i needed.Good quality,reasonable price.Thank you.
;
Acurate informations inside the SM and I could repair my old Sansui SC-3330 without any problems. Thanks.
;
I used it to repair a NAD 7030, but unfortunately, the 7045 is different !
But documentation was useful.
;
Content A4 and A3 format pages. Exactly what I needed to restore my old receiver.
CTV990107
Month of Issue: Classification:
CTV991202 TELEVISION TECHNICAL BULLETIN
Month of Issue: December 1999 Classification: White Page 1 of 1
TELEVISION TECHNICAL BULLETIN
PHILIPS CRT Original deflection yoke PWB shown on left
January 1999 White Page 3 of 3
MODELS
66DW18H
76DW18H
76EF19H
76EF20H
CONNE
Orange Yellow Green
Connector 1
SYMPTOM The following problems can occur on the 100Hz PWB.
Red Yellow Red Orange Green
� � �
�
Intermittent digital noise on the picture Intermittent mosaic squares on the picture Mosaic effect if the 100Hz PWB is tapped Red, green or blue screen if the 100Hz PWB is tapped
KC lead
CAUSE
Problems around the field mixer IC, SDA9270. � � IC6108 in the 66DW18H and 76DW18H IC6105 in the 76EF19H and 76EF20H
ACTION
Carry out the following counter measures. 1. Make sure that there are no dry joints on the Mother PWB 2. Resolder IC6108/IC6105 by reflowing the device - it is not necessary to remove IC6108/IC6105 Note that you can operate the 100Hz PWB with the shield cans removed. It is important that these are returned to there original condition when the job is completed.
To change the deflection yoke wiring from a Thomson CRT to a Philips CRT, proceed as follows 1. 2. 3. Unsolder both the green and yellow (FV) and red and orange (FH) leads from the deflection yoke PWB. Solder these leads to the Philips CRT as shown above. Replace wire KC (QCNW-2775BMZZ) that connects from the CRT socket PWB to the neck of the CRT with lead QCNW-2757BMZZ.
Sharp Electronics (UK) Limited
Sharp Electronics (UK) Limited Originator AvW Supervisor Approval Date / / Reference SP84001X Revision 2 White � Carry out as required, Yellow � Carry out as required and whenever the unit comes in for service, Red � Carry out on all units
Reference JR031299-1 Revision 2 White � Carry out as required, Yellow � Carry out as required and whenever the unit comes in for service, Red � Carry out on all units
|
|
|
> |
|