75171.fm5 Page 12 Friday, May 12, 2000 12:05 PM
AKR 904 IX-1
PRODUCT SHEET THE CONTROL PANEL
FIG. 1 1. 2. 3. 4. 5. Control panel. Grease filters. Grease filter handles. Halogen bulb. Telescopic flue.
Cleaning the grease filter
Wash the grease filter once a month, or whenever the grease filter saturation indicator flashes (Extraction speed indicator 2). 1. Unplug the appliance or disconnect the mains power supply. 2. Remove the grease filters (Fig. 1 - a,b,c). 3. After cleaning the grease filter, remount in reverse order ensuring the entire extraction surface is covered.
1. Extraction OFF button. 2. Extraction ON speed increase button - 1 � 3 � 1...... 3. Extraction speed indicator 1. 4. Extraction speed indicator 2 and grease filter saturation indicator (when flashing). 5. Extraction speed indicator 3 and carbon filter saturation indicator (when flashing): this function is normally deactivated. In order to activate it press button 1, then buttons 2 and 7 at the same time, until the carbon filter saturation indicator starts flashing. To deactivate the function repeat the operation until the carbon filter saturation indicator stops flashing. 6. Intensive extraction speed indicator. 7. Timed intensive speed button: the hood operates at this speed for 5 minutes and then returns to the previous settings. This function can be cancelled by pressing button 1 or 2. 8. Light OFF button. 9. Light ON button. Reset filter indicator: Press the button OFF until LED 2 and/or LED 3 stop flashing.
Replacing bulbs
1. Unplug the appliance or disconnect the mains power supply. 2. Unscrew the lighting unit (Fig. 2 - d). 3. Remove the burnt-out bulb (Fig. 2 - e). Replace with 20W max.halogen bulbs only. 4. Screw the lighting unit back in place
Fitting or renewing the carbon filter:
1. Unplug the appliance or disconnect the mains power supply. 2. Remove the grease filters (Fig. 1 - a,b,c). 3. Fit the carbon filter by fixing it with the two screws supplied (Fig. 3 - f). 4. If the carbon filter needs renewing, remove the old filter and fit a new one. Change the carbon filter once a year and, in any event, every time the carbon filter saturation indicator flashes (Extraction speed indicator 3). 5. Refit the grease filters
FIG. 2
FIG. 3
5019 100 75171
PL CZ
SK
H