Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Thanks God for the internet and thanks for the service like this - proffessional solution on time.
;
About the service it's very fast and reliable. About the manual the quality is high enough to read even the tiniest details on the wiring diagrams so you can't ask much more than that, let it alone for a manual of a product from 20 years ago. Thank you, very satisfied.
;
The downloaded quality was as good as the orignial
;
This is a great and complete Service Manual for the Sharp GF8585HB. Giving full and detailed technical insight. Good to find these manuals online.
;
Everything was ok with the manual. If I have a small complaint, is that I ordered it during the weekend and I think you guys were closed. But I did receive it late Sunday. I will surely order from you again
72GF-63E
IMPORTANT SERVICING NOTES
Only qualified service personnel are allowed to carry out mintenance and repair of this receiver.
SERVICING OF HIGH VOLTAGE SYSTEM AND CRT
It is important that the static charge is removed from the high voltage system when carrying out work on the receiver. This can be achieved by connecting a 10K resistor (with a suitably insulated lead) from the CRT cavity connector to the CRT ground tag. This must be carried out with the AC supply disconnected from the receiver. Note the following: · The CRT in this receiver employs Integral Implosion Protection. · If the CRT has to be changed it MUST be replaced with the correct type for continued safe working. · DO NOT lift the CRT by its neck. · When handing the CRT, ensure that shatterproof goggles are worn. · Ensure that the CRT is discharge before handling.
X-RAY
This receiver is designed to keep any x-ray emission to an absolute minimum. Some fault conditions and servicing procedures may produce potentially hazardous x-ray radiation levels. This is a problem when in close proximity to the receiver for long periods of time. To reduce any risks associated with this, please observe the following precautions: 1. When undertaking any servicing on this chassis, DO NOT increase the EHT to more than 35 KV. 2. Ensure that during normal operation the EHT does not exceed 32KV±1.5KV (at a beam current of 1300mA). This level has been pre-set in the factory. Always check that this level has not been exceeded after carrying out any repair on the receiver. 3. DO NOT replace the CRT with any other type than that specified in the parts listing as this may cause excessive x-ray radiation.
BEFORE RETURNING THE RECEIVER TO THE CUSTOMER
In addition to the above checks, the following should also be carried out before returning the receiver to the customer. 1. Inspect all the leads to ensure that they are dressed correctly and that they are not obstructed or pinched by any other parts. 2. Ensure that all protective devices are in good condition. These will include non-metallic control knobs, insulating fish papers, cabinets backs, compartment covers or shieds, mechanical insulators, etc.