Who's Online
There currently are 5923 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
The only reason I gave this less than 4 stars, is because it shouldn't take 24 hrs to have the download available. I was surprised to find that I had to wait until the next day to be able to download the manual that I paid for.
The manual itself is the correct manual.
;
Excellent replacement for original Owner´s Manual. I am totally satisfied!
;
Great service. Manual is as advertised and delivered when promised.
;
Perfect quality, highly appreciated service !!!
Fast delivery of the download info, no issues at all. Recommended E-manual shop !!!
;
hi owners manual- crew,
i am very satisfied about the trade with you.
if i need some other manuals, i will contact you again.
thanks
frank kappler
Supplementary Notes
How to connect the VM-3100Pro and the ADA-7000
Connection
Connect the VM-3100Pro and the ADA-7000 with the R-BUS cable attached in the ADA-7000 box.
Booting up
Turn the power on the ADA-7000 first, then VM-3100Pro.
Sampling clock setting
If clock source has not been set, noise may be generated from the audio output on the ADA-7000 and the VM3100Pro. While setting the clock source, please turn down the master and monitor level, and turn up again after the setting is finished. Set the sampling clock of the ADA-7000 and the VM-3100Pro as follows.
Clock Source on the ADA-7000: Master clock on the VM-3100Pro: R-BUS INTERNAL
ADA-7000 setting
Check if the clock source on the ADA-7000 is set to R-BUS. When the ADA-7000 is booted up, the clock source is set to R-BUS. * Refer to ADA-7000 Owner�s Manual p. 6 �Clock source.�
VM-3100Pro setting
Set the master clock of the VM-3100Pro to INTERNAL as follows.
1. 2. Hold down [SHIFT], and press [DIGITAL IN]. Press [F1 (�INT)].
* Sample rate of the VM-3100Pro is fixed to 44.1kHz. If you use the VM-3100Pro and the ADA-7000 in combination, the ADA-7000 works in 44.1kHz sample rate. * If you set the clock source differently, please refer to the ADA-7000 Owner�s Manual p. 6 �Clock source� and the VM-3100Pro Owner�s Manual p. 52 �Inputting signals from digital devices.�
How to connect the VSR-880 and the ADA-7000
Connection
Connect the VSR-880 and the ADA-7000 with the R-BUS cable attached in the ADA-7000 box.
Booting up
Turn the power on the ADA-7000 first, then VSR-880.
Sampling clock setting
Set the sampling clock of the ADA-7000 and the VSR-880 as follows. If clock source has not been set, noise may be generated from the audio output on the ADA-7000 and the VSR-880. While setting the clock source, please turn down the master and monitor level, and turn up again after the setting is finished.
Clock Source on the ADA-7000: Master clock on the VSR-880: R-BUS INTERNAL