Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
The owners manual is very good. all my how to questions were answered in detail.
;
Irrespectively of this manual exist only germany language, it's useful - although i need some additional task to translate: My english is bad, but usable - but i really dont speak germany. :)
;
Excellent service from this company (including a total refund on an earlier purchase when through no fault of the company the manual was incomplete). I have purchased several manuals which I have been very satisfied with, as I am with this one. Highly recommended.
;
It was easy to order and received exactly what I needed. Only complaint would be the 24 hours you have to wait.
;
Manual was delivered in a timely manner and was all in English as advertised. The manuals I received when we moved into our flat were in German, Italian, and French. Having never used a steamer before, and not speaking/reading German very well, I needed an English Manual. this was a huge help.
Minimum Clearances to Combustible Surfaces
� Minimum clearance to rear wall is 0 inches. � Minimum clearance to a vertical right or left side wall is 3 inches. � Minimum clearance to counter top/cabinet on each side is 0 inches. � Minimum of 30 inches between top of cooking surface and bottom of an unprotected wood or metal cabinet.
Slide-in Installation
Backrail
1-3/4"
30" Min. 0" 13" Max.
3" Both Sides
18" Min.
� For a manufactured counter top, with or without a backsplash, make cutout keeping rear dimension as illustrated. The backrail on back of range slides over manufactured counter top creating a tight fit. � Backrail may not reach back wall because of counter top. Corner of backrail can be clipped off with a pair of wire cutters for a tighter fit.
Duct Requirements
0"
� Duct should be 6 inch round metal ducting. Island or peninsula installations may require 31/4 X 10 inch � � duct. To ensure proper ventilation, duct work must not exceed 60 equivalent feet. Curved fittings should not account for more than 50% of duct length. Flexible duct is not recommended because of irregular interior surface. If flexible duct is to be used, one foot is equal to 2 feet of metal duct. NEVER USE PLASTIC TYPE DRYER DUCTING. Do not vent into an attic or crawl space. Duct range outside. Flexible duct elbows are equal to twice as many feet as smooth metal elbows. Never install two elbow fittings next to each other. Two elbows installed together create a poor vent path and insufficient ventilation. Seal all duct joints tightly using duct tape. Openings left in ducting allow smoke and odor to escape inside house. For best performance, do not use more then three 90° elbows. 6 inch transition duct provided must be mechanically secured to exhaust blower outlet. Secure transition duct using two screws provided.
301/8"
�
Special Counter Top Conditions
Irregular Cabinet and Counter top Heights Counter tops such as ceramic tile tops cause cabinet and counter top to be higher than 36 inches. Follow instructions below when counter top is higher than 36 inches. 1. Raise leveling legs to maximum level. 2. Measure from floor to side trim. If measurement is less than height of counter top, floor must be shimmed. 3. Shim floor using a piece of plywood same size as range opening. Secure plywood to floor. Plywood must be as secure as original flooring. 4. Install anti-tip bracket and slide range into place. Island or Peninsula Installation Island or peninsula installations with 24 inches deep base cabinets must use flush back cabinets with no rear toe space to avoid range interference. If a rear toe space is desired, use 27 inches or deeper base cabinets.
� � �
�
� �