Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
The quality of this manual is good. It has all schematics and setup information for both the MDS-B3 and the MDS-B4. The scan quality is quite good, all pages are readable, This service manual also contains scans of the operating instructions from the User manual.
;
Quick site processing. A complete and very useful manual with all details. Thank you!
;
Das Service Manual war von der ersten bis zur letzten Seite sehr informativ und hilfreich. Die Darstellung aller Teile war klar und der Text gut lesbar.
Vielen Dank, das war nicht der letzte Download bei ownner-manuals.com.
;
It's a grate service manuals.Have many details and the writing it's so clear.You have all you want in manual,nothing missing,belive me.I'm verry satisfied of this manual.
;
Great scanned service manual
Usefull informations.
I will buy again!
Best Regards
AJ-5030U/C 3. 21. All FAX/TEL entry mode
This function simplifies the registration of FAX/TEL numbers during aging. [Presetting] (Please remember that this should be performed before entering the diag mode.) A number to be referred to should have been registered as the onetouch number 01. (If nothing has been registered or the mail setting has been registered here, this function is not activated.) [Execution] the FAX/TEL number registered as one-touch number 01 to 02 ~ 10. (One-touch numbers assigned as polling keys are not copied into.) y the FAX number registered as one-touch number 01 to rapid numbers 01 ~ 89. Names to be registered should be as follows:
1Copy 2Cop
RAPID SPEED
Rxx Sxx
x x : number x x : number
(15 digits from the first letter of the name registered as RAPID01)
FAX/TEL ENTRY
[START]
FAX/TEL ENTRY SETTING
After the completion of setting change Proceed to the next diagnostic.
3. 22. Dial test mode
This mode checks whether or not the dialing is performed correctly in two dial modes. All data that can be dialed is automatically called in the PB and DP modes. After entering this mode, the following operations are automatically executed and terminated. The correctness of dialing is judged by an external instrument connected to the unit with a line cable. This mode employs the normal auto dial processing. (Therefore, the signal transmit time and minimum pause are the same as those in the normal processing.) The same measurement result as that in the normal dial mode can be obtained in this mode. DIAL TEST MODE
[START]
DIAL TEST MOE The line is connected to dial in the PB mode. No.=1 2 3 4 5 6 7 8 9 0 # PB MODE DIALING A number is dialed following No.=1 2 3 4 5 6 7 8 9 0 # the normal auto dial procedure in the PB mode.
Immediately after dialing
DIAL TEST MODE
The line is cut.
500ms elapsed
DIAL TEST MODE No.=1 5 9 0 DP MODE DIALING No.=1 5 9 0 DIAL TEST MODE
The line is connected to dial in the DB mode.
A number is dialed following the normal auto dial procedure in the DB mode.
Immediately after dialing The line is cut.
Proceed to the next diagnostic.