Text excerpt from page 69 (click to view)
The black balance must be adjusted in the following cases. When the unit is used for the first time When the unit is first used after an extended period of non-use When the unit is used under conditions where the ambient temperature has changed by a wide margin When the gain selector value is changed When the SUPER IRIS button setting is changed (when setting is changed to +30 dB) When the gamma ON/OFF is changed
Adjusting the Black Balance
1
Set the switches as shown in the figure.
MENU SET/OFF: OFF
OUTPUT: CAM
2
Press the AUTO W/B BAL switch to the ABB side and then release the switch. The switch returns to the center and the black balance is automatically adjusted.
AUTO W/B BAL switch
3
During the adjustment, the following message will appear on the viewfinder screen. (However, the message appears only when the display mode is set to � or � .) 2� 3�
ABB ACTIVE
.
The lens iris automatically goes to the � CLOSE� position during the adjustment. Message during adjustment