Who's Online
There currently are 5624 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Thank´s for your help, I already recived these manual from you
;
Thank you for your manual It has the basic things to and i use the Oszi for Longer Time.
THX
;
Actually, I was looking for this information for 3 years!...now thanks to you, the manual is on my hands and of great help, cause I understand now where I was doing wrong connections and wires...excellent, I'll be back to you if in need, thank you.
;
This manual covers the main equipment features only. While it also includes the procedure for saving and loading from the now long obsolete memory cards it does not mention the how to operate with the optional floppy drive interface so I am still at a loss about how to use this! Note that there is a separate manual covering the MIDI interface and programming via the keyboard, not included in this download. You will also need to get hold of this if you want to use the MIDI interface properly. Basically there is little difference between this manual and the free to download manual for the similar PR60 model.
;
Good list of manuals. I found a very rare one and easily get. Should be promptly to download, as we must to wait hours even after confirmed payment.
DIMENSIONS OF THE COOKTOP AND THE WORKING SURFACE (in mm)
NOTE:
If the distance �A� between the wall cabinets is between 660 mm and 680 mm, the height �B� must be a minimum of 520 mm. If the distance �A� between the wall cabinets is greater than the width of the cooktop, the height �B� must be a minimum of 400 mm. In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance. CATEGORY II2H3+
Type of burner Gas type code No. Injector marking ø 100/mm Rated Rated thermal consumption flow rate kW 3.00 1.65 1.00 3.00 1.65 1.00 3.00 1.65 1.00 286 l/h 157 l/h 95 l/h 218 g/h 120 g/h 73 g/h 214 g/h 118 g/h 71 g/h Low thermal nominal flow rate kW 1.20 1.00 0.70 1.20 1.00 0.70 1.20 1.00 0.70 Gas pressure min. rated max.
INJECTOR TABLE
Type of gas used
High-speed Medium-speed C1 (Methane) G 20 Auxiliary LIQUID High-speed PETROLEUM GAS Medium-speed (Butane) G 30 Auxiliary C4 LIQUID High-speed PETROLEUM GAS Medium-speed (Propane) G 31 Auxiliary
NATURAL GAS
140 103 86 88 66 52 88 66 52
17
20
25
20
28-30
35
25
37
45
Type of gas used G 20 G 30 G 31 20 mbar 28-30 mbar 37 mbar
Type of appliance 4 gas 4 gas 4 gas
Total rated thermal flow rate kW 7.30 7.30 7.30
Total rated consumption 695 l/h 531 g/h 521 g/h
Air needed for combustion m3/h 14.6 14.6 14.6
|
|
|
> |
|