Shopping cart is empty
 
English Polski Spanish 
Search For a Manual
 

(e.g. AA-V20EG JVC, ZX-7 Sony )
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Who's Online
There currently are 4989 guests and 
4 members online.
Categories
Information
Featured Product
Home >> SHARP >> AR-FX4 Service Manual
 
 0 item(s) in your cart 

SHARP AR-FX4
Service Manual


Tweet about this product and get $1.00 of store credit for instant use!
  • Contains Circuit Diagrams
  • Download
  • PDF Format
  • Complete manual
  • Language: English
Price: $4.99

Description of SHARP AR-FX4 Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagrams, printed circuit boards, repair tips, wiring diagrams, block diagrams and parts list. Service Manual ( sometimes called Repair Manual ) is used mainly by technicians.

If You just want to know how to use Your tv, video, mp3 player etc. You should look for Owner's Manual. After placing order we'll send You download instructions on Your email address.

The manual is available in languages: English

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 PCM100L/LB JVC Service Manual by Dušan Demovi?;
OK?..manual is complet and helpfull... for repairing such a old and rare boombox like JVC PCM it is necessary...
 CCU-700AP VOLUME1 SONY Service Manual by Ralf Made;
Super Anleitung. Ordentliche Auflösung. Das ganze noch in Deutsch wäre zu schön. Alle Datenblätter sind sauber Kopiert und alle Leitungswege sind sauber ausgeführt
 PVW2650P VOLUME 1 SONY Service Manual by Artur Łukasik;
Thanks God for the internet and thanks for the service like this - proffessional solution on time.
 3681 ALPINE Service Manual by Luís Visentin;
About the service it's very fast and reliable. About the manual the quality is high enough to read even the tiniest details on the wiring diagrams so you can't ask much more than that, let it alone for a manual of a product from 20 years ago. Thank you, very satisfied.
 A-1200P SANSUI Service Manual by Brian Smith;
The downloaded quality was as good as the orignial

Text excerpt from page 45 (click to view)
SW38 No.5, No.6 Inhibited to use SW38 No.7 Transfer function
Used to set Enable/Disable the transfer function. Default: 0 (Inhibit)

SW42 No.1 Direct send recall Allow/Inhibit
Used to set allow/inhibit of wait for recall in direct send. Default: 1 (Allow)

SW42 No.2, No.3 Inhibited to use SW42 No.4 Manual/Auto reception auto swiching
Used to set whether automatic reception is made or not when ringing is made the number of auto switch call times in manual reception. Default: 0 (Inhibit)

SW38 No.8 Inhibited to use SW39 No.1 � No.3 Call time setup in automatic transmission (T0 timer setup)
Used to set the call time when call does not reach the other party in auto send mode. The set range is 30 to 60 sec in the increment of 5 sec by binary input of "(5 sec x N) + 30 sec)". "N" can be set in the range of 0 to 7. When set to 7 (65 sec), it is the same as setup of 45 sec. Default: 45sec (N=3)

SW42 No.5 � No.8 Number of auto switch calls of manual reception � auto reception
When the above setup is allowed, automatic reception is made at the set number of times. The set range is 1 to 9 times. Default: 9 times

SW39 No.4 � No.8 Inhibited to use SW40 No.1 � No.4 Number of times of recall in error
Used to set the number of recall times in case of a communication error. Setup is made in the range of 0 � 1 times by binary input. When set to 0, recall is not made. Default: 1 time of recall

SW43 No.1 � No.5 DTMF signal send time
Used to set the send time when sending DTMF signal. Setup is made in the range of 60 � 310ms by binary input of N in "10(ms) x N" in the increment of 10ms. N is set in the range of 0 � 31. When N is set to 0, it is the same as 110ms (N=11). Default: 110ms

SW40 No.5 � No.8 Number of times of recall in busy
Used to set the number of recall times in case of busy state of the other party or when call does not reach the other party. Setup is made in the range of 0 � 14 times by binary input. When set to 0, recall is not made. Default: 2 times of recall

SW43 No.6 � No.8 Maintenance cycle
Setup for judgment of consumable parts notification when using the F.A.S.T. function. This setup should be the same as SIM21-2 setup. Default: 0 0 1 (50K)

SW44 No.1 � No.4 Scan effective image area (OC) Main scan Left edge image loss
Used to set the left edge image loss of main scan in OC scan of FAX. The set value of SIM 50-8 is reflected.

SW41 No.1, No.2 Tone/Pulse default setup
Employed line setup (Dial setup) Selection of 10PPS, 20PPS, and TONE is allowed. The setup items are as follows: bit 1 0 0 1 1 2 0 1 0 1 : : : : 10PPS 20PPS TONE Similar to TONE.

SW44 No.5 � No.8 Scan effective image area (SPF) Main scan Left edge image loss
Used to set the left edge image loss of main scan in SPF scan of FAX. The set value of SIM 50-8 is reflected.

SW45 No.1 � No.4 Scan effective image area (OC) Main scan Right edge image loss
Used to set the right edge image loss of main scan in OC scan of FAX. The set value of SIM 50-8 is reflected.

Default: 1 0 (TONE)

SW41 No.3 Telephone line menu
Used to set whether Tone/Pulse setup is displayed on the menu or not. Default: 0 (Fixed to �Allow�)

SW45 No.5 � No.8 Scan effective image area (SPF) Main scan Right edge image loss
Used to set the right edge image loss of main scan in SPF scan of FAX. The set value of SIM 50-8 is reflected.

SW41 No.4 Maintenance system
Setup of the model for judgment of consumable parts system when using the F.A.S.T. function.

SW46 No.1, No.2 Inhibited to use SW46 No.3 Priority in the day of week
Used to set the recording sequence of the day of month and the day of week if the date is in the sequence of day, month, and year. Default: 0 (NO)

SW41 No.5 F.A.S.T mode
Used to set Enable/Disable of FAST operation. To enable FAST operation, the serviceman must change this SW setup. Default: 0 (NO)

SW46 No.4 Inhibited to use SW46 No.5 Daylight saving tive
Used to set Enable/Disable of Daylight saving time. Default: 0 (Inhibit)

SW41 No.6, No.7 Sequence of year/month/day in LCD, report, and sender record
Used to set the sequence of year, month, and day in the display, report, and sender record.

SW46 No.6 � No.8 Inhibited to use SW47 No.1 � No.5 Time specification print 1 (O�clock) in the communication report table
Used to set "o�clock" of the time (o�clock, min) when specifying the time in the communication report table. Setup is in the range of 0 � 23 (o�clock) by binary input. When set to 24 � 31, the time is set to 0 o�clock. Default: 0 o�clock

SW41 No.8 Time display format
Used to set the sequence of year, month, and day in the LCD display, report, and sender record. When set to 0, time is indicated in 24H format. When set to 1, time is indicated in AM/PM format. Default: 1 (AM/PM)

AR-FX4 SOFT SWITCH DESCRIPTIONS - 26

You might also want to buy

$4.99

ARFX4 SHARP
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…
>
Parse Time: 0.185 - Number of Queries: 108 - Query Time: 0.041