3. Adjust the angle of the ADF.
Loosen the two securing screws for the angle adjusting panel attached to the hinge angle and then fasten the loosened screws while raising the angle adjusting panel completely.
5. Connect the ADF tray connector.
Thread the M4 x 8 tray securing screws (included parts) part way into their holes, then connect the tray connector.
Tray connector
Tray securing screws
Connector on the ADF
Angle adjusting panel securing screws Long hole Long hole
6. Attach the ADF tray.
Loosen the two ADF tray securing screws, install the tray as shown in the figure, and fasten the tray securing screws.
Hinge Angle adjusting panel
NOTE: Be sure to check that the protrusion of the angle adjusting panel is securely inserted into the long hole of the hinge.
Tray securing screws
4.Connect the ADF connector.
Remove the connector cover securing screw to remove the connector cover from the copier�s rear cover. Next, connect the ADF connector to the connector on the copier, and fasten the screw on the ADF connector completely. Plug the copier into a grounded outlet and turn on the power switch. Then follow the procedure below.
Tray
7. Adjust the center of the copy.
Connector on the copier
ADF connector
Set an original in the ADF tray and make a copy. When the copy is off center as shown in Fig. 1 or Fig. 2, loosen the two tray securing screws and adjust the tray by moving it in direction A or B as shown in the figure below.
Mark Tray securing screw
B
Screw
A
Securing screw
Connector cover
8. Set the mode. � Set the mode with the key operation of the copier.
P C Clear 2 6 1
Press the corresponding operation key on the display.