|
Who's Online
There currently are 5945 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
The manual was complete and extremely helpful in both diagnosing the problem I was having as well as fixing it. Excellent quality. I will getting additional manuals in the future.
;
Exactly the JVC service manual and schematics that I was looking for - delivered just hours after order. Will do business again!
;
This is a fantastic site, ad I have been a returning satisfied cusumer!
Thanx for a great sevice!
;
Je suis audiophile belge, électronicien et créateur d'enceintes acoustiques.
J'ai apprécié la qualité des documents fournis. Ils sont très lisibles, ils peuvent être agrandis sans problème et ils sont complets. Pour moi, c'est parfait. Pour cette qualité, je suis d'accord de payer. Et le système de paiement et d'envoi est simple. Merci, continuez comme cela.
Frédéric
;
The cover page was a little scary, very dark but readable. The remainder of the document was better copy and easily readable. Why would I give 5 Stars? (1) PRICE, (2) AUTHENTICITY, It was the real deal, filled with service information, including the specific information I required. (3) PRIVACY, I didn't start to get slammed with spam. (4) EASY TRANSACTION. Painless. (5) COMPLETE, I have found several manuals here, that I could find nowhere else. (6) I will be a repeat customer!
AV-14F3/AV-1435 AV-1435EE/AV-1435TEE AV-14FMT3/AV-1438 AV-14FMG3/AV- 14FMG 3B
Measuring instrument Signal gener ator Remote control unit
Item Ad justment of VER. LIN. & VER. SCURVE
Test point
Ad justment part 4. VER. L IN. 5. VER. SCURVE � When the vertical
Description linearity has been deteriorated
rem arkably, perform the following steps. 15. Input a cross -hatch signal. 16. Select 4. VER. LIN. with the MENU �/� key. 17. Set the initial s etting value of 4. VER LIN. with the MENU - / + key. 18. Select 5. VER. SCURVE with the MENU �/ � key. 19. Set the initial setting value of 5. VER. SCURVE with the MENU - / + key.
T OP
CEN TER
20. Adjust 4. VER. LIN. and 5. VER. SCURVE so that the spaces of each line as shown in Fig.3 on TOP, CENTER and BOTTOM become uniform.
BOTT OM
Fig.3
Make sure that the adjustment is properly done on the screen of 60Hz mode. [NOTE] " Adjust to make both 50Hz & 60Hz are the same v. size and fine straight line. " When adjust again, adjust 50Hz mode first.
" When adjust in 60Hz mode, only 60Hz mode is adjust.
VSM PRESET SETTING
Item Measuring instrument Remote control unit Test point Ad justment part Description
Setting of VSM PRESET
TINT COLOUR BRIGHT CONT . SHARP
1. Enter the SERVICE MENU. 2. Select 4. VSM PRESET from the SERVICE MENU. 3. Select BRIGHT with the PICTURE MODE key. 4. Adjust the MENU �/� and MENU - / + key to bring the s et values of TINT � SHARP to the values shown in the below table. 5. Respectively select the VSM PRESET mode for SOFT and STANDARD, and make s imilar adjustment as in 3 above.
�
BRIGHT TINT COLOUR BRIGHT CONT. SHARP / :SELECT DISP : EXIT ** ** ** ** **
VSM PRESET VSM Setting Item TINT COLOUR BRIGHT CONT SHARP BRIGHT +15 +15 +15 +30 +15 STANDARD SOFT
� � �
+15
� � �
+11 +12
- / + : OPERATE
�
28
No. 52026
|
|
|
> |
|