Well.. I'd searched for this manual and although I found many copies online I was pleased to find your website with a well balanced pricing system and easy to search and follow links. That together with the very quick response time was just what I was looking for.. being a very impatient tech.. ;-) I had the service manual in front of me within a short time.
Bookmarked.. and you can bet I will always come here first for my service & user manuals..
best regards
Ed(Tony) Foley
G7WHK
The service manual when downloaded and printed out was clear and easy to read. I would have liked to have been able to enlarge some details, but this was not possible as the file permissions did not allow this. The service was very good. The time taken from placing my order to downloading the document was only a few minutes.
Description Receive a RED test pattern. Set < 4 : 3 aspect mode >. Select < ADJUST 12 > from SERVICE MENU. Change horizontal shift till the picture is horizontally centered. Check whether this adjustment is correct after completing Service Mode Adjustment. 5. Set < 16 : 9 aspect mode >. 6. Adjusts with the step which is the same above from 3 to 4 about the 16 : 9 aspect mode, too.
VERTICAL SLOPE Adjustment
Signal generator
Adjust 13 ( 4 : 3 ) Adjust 24 ( 16 : 9 )
1. 2. 3. 4.
Receive a cross-hatch signal. Set < 4 : 3 aspect mode >. Select < ADJUST 13 > from SERVICE MENU. Change vertical slope till the size of squares on both the upper and lower part of test pattern become equal to the squares laying on the vertical centre of the test pattern. Check and readjust VERTICAL SLOPE item if the adjustment becomes improper after some other geometric adjustments are done. 5. Set < 16 : 9 aspect mode >. 6. Adjusts with the step which is the same above from 3 to 4 about the 16 : 9 aspect mode, too.
VERTICAL AMPLITUDE Adjustment
Signal generator
Adjust 14 ( 4 : 3 ) Adjust 25 ( 16 : 9 )
1. 2. 3. 4.
Receive a PAL test pattern signal. Set < 4 : 3 aspect mode >. Select < ADJUST 14 > from SERVICE MENU. Change vertical slope till horizontal black lines on both the upper and lower part of the test pattern become very close to the upper and lower horizontal sides of picture tube and nearly about to disappear. Check and readjust VERTICAL AMPLITUDE item if the adjustment becomes improper after some other geometric adjustments are done. 5. Set < 16 : 9 aspect mode >. 6. Adjusts with the step which is the same above from 3 to 4 about the 16 : 9 aspect mode, too.