Who's Online
There currently are 5741 guests and 40 members online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Great tape deck manual!
I'm very positively surprised, because it is a very long manual, lot of pages, drawings, diagrams, description of how to make the alignment and adjustment procedures.
It is as good as the old "Naka" manuals from the 1970's - if somebody have seen them, they know what I mean by that.
I recommend to buy this very much !
;
I am a vintage hifi collector. No way to fix that device without the appropriate service manual...thanks to your site I got it and every thing is easier now. I got the manual right after ordering: fast cheap accurate ... thank you
;
Wonderful job clear. Qick fantastic. These people are really good. If even a problem arise they are wonderful assisting you. These scheme is so net despite this is a very old TV. Thank you for everything!!!!!!!!
;
Detailed schematic diagram, manual for professionals
;
Good service manual,exploded view,adjusment and test point locations,head alignment,mechanical checks and adjusments,all perfect.
AV-29LS AV-29LH
AV-29LX AV-2908TEE
PURITY AND CONVERGENCE ADJUSTMENTS
Note: The final adjustment of CONVERGENCE must be done after the FOCUS adjustment. (CONVERGENCE is changed by FOCUS adjustment.) When makes difference by FOCUS adjustment, should be reconfirming PURITY adjustment.
WEDGE DEFLECTION YOKE
PURITY ADJUSTMENT
1. Demagnetize CRT with the demagnetizer. 2. Loosen the retainer screw of the deflection yoke. 3. Remove the wedges. 4. Input a green raster signal from the signal generator, and turn the screen to green raster. � P/C MAGNETS 5. Move the deflection yoke backward. 6. Bring the long lug of the purity magnets on the short lug and position them horizontally. (Fig. 2) 7. Adjust the gap between two lugs so that the GREEN RASTER will come into the centre of the screen. (Fig. 3) 8. Move the deflection yoke forward, and fix the position of the deflection yoke so that the whole screen will become green. 9. Insert the wedge to the top side of the deflection yoke so that it will not move. 10. Input a crosshatch signal. 11. Verify that the screen is horizontal.
Short lug Long lug
CRT
P
46
P/C MAGNETS
P : PURITY MAGNET 4 : 4 POLES (convergence magnets) 6 : 6 POLES (convergence magnets) Fig. 1
PURITY MAGNETS
12. Input red and blue raster signals, and make sure that purity is properly adjusted.
Bring the long lug over the short lug and position them horizontally.
Fig. 2
(FRONT VIEW)
GREEN RASTER
CENTRE
Fig. 3
34