|
Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Manuals were delivered promptly and were correct as advertised. No issues with the download link which was provided promptly after everything was processed. Very pleasant experience
;
Paid for service manual & got the download fast - worth a visit if you need a service manual
;
It's the manual, I am searching for. Now I am able to repair my Braun A501.
;
Great service manual. Unfortunately on page no. 41 there are some details which i can't read.
;
Wonderful service... doubt that I could have made the repairs to my turntable without this service manual. Great help!
Well worth the price paid!
1
2
3
4
Symptoms in case of poor adjustment: Error efficiency deteriorated: 10 -3 (Optimum value: 10-4 or lower)
A
High jitter of the RF signal RF waveform deformed Unstable operation in tracking closing and servo control Caution: Avoid exposing your eyes to laser beams for a long time. Preparation for adjustment: Clean both ends of the shafts. Use brand new skew screws supplied with the service kit GXX1258. Procedures: 1. Place the DVD mechanism module upside down. To avoid the disc from being robbed when it is turned upside down, first put a coin of about 1.5 mm on the table, then turn the disc upside down and set it so that the 1 in the figure comes to the point immediately above the coin. 2. After replacing the pickup (by referring to the procedures of "Removing the Pickup."), roughly adjust the three skew screws through visual check so that the pickup is mounted in parallel to the CRG chassis around the inner and outer tacks. 3. Connect an oscilloscope as shown in the connecting diagram. 4. Turn on the power of the product. Load the test disc (GGV1018). 5. In the front-end test mode, set the disc type to DVD layer 1. Then, turn on the power. Move the pickup toward the inner tracks. 6. Turn on the laser diodes. 7. With the focus servo closed, complete all automatic adjustments. Close the tracking servo, and then complete all automatic adjustments. 8 Follow the next procedures, from 8-1 to 8-5, and adjust the (three) skew screws. 8-1 Move the pickup toward the inner track and turn the skew adjustment screw C so that the RF level of oscilloscope becomes the maximum. (Tangential adjustment at the inner track position: Adjust the flatness of the disc at the inner track position with the adjustment screw C) 8-2 Move the pickup toward the outer track and turn the skew adjustment screw B so that the RF level becomes the maximum. (Tangential adjustment at the outer track position: Adjust the flatness of the disc at the outer track position with the adjustment screw B) 8-3 Leave the pickup at the outer track position and turn the skew adjustment screws A and B in the same direction alternately one quarter at a time (A�B�A�B ���) so that the RF level becomes the maximum. (Radial adjustment at the outer track position: Keeping the flatness at the outer track position, adjust the flatness of the whole disk with the adjustment screws A and B) 8-4 Move the pickup toward the inner track and turn the skew adjustment screw C so that the RF level becomes the maximum. (Tangential adjustment at the inner track position: Adjust the flatness of the disc at the inner track position with the djustment screw C) 8-5 Repeat the steps from 8-2 to 8-4 three times, and adjust at the position where the RF level becomes the maximum. 9. Turn off the power in the test mode. After confirming that the disc has stopped, eject the disc. 10. Adjust with a screw rock the shaft and skew adjustment screw to the same state as initial one. Skew adj. screw Apply glue Skew adj. screw
B
C
D
Prevent applied glue Shaft from extending beyond this position.
Prevent applied glue from extending beyond this position.
E
C 1 B
A
F
190
AVIC-D8000/XU/CN5
1 2 3 4
|
|
|
> |
|