|
Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
I was at first dubious about payiong for downloaded manuals but having done so, I was extremely impressed with quality of the two manual I ordered, well worth the small price I paid.
I would highly recommend these to my friends.
;
reasonable price for the schematic - the service is perfect, all as expected and pointed by instructions - good scan of the original plans - thank you!
;
Manual was just as described!!! I odered it and in less than a day was able to download it and the text was clear and pages were all complete just as the original manual was. Purcashed this for a friend and they were more than happy. Perfect all around!
;
Excellent service and prompt delivery. But it's not a manual - only 4 pages wiring diagrams.
Thanks.
;
The manual I purchased was exactly what I needed to repair my Toshica television. The manual contained schematics and troubleshooting information that was very helpful.
!~
AVM 930 -MW L2
l
Diode check The high voltage diode is built-in in the same case as the HV capacitor. Unplug the oven, discharge the capacitor and remove wires tram it. With an ohmmeter set on the highest scale, measure the resistance ac ross terminal "C" and capacitor case. Reverse the meter leads and again observe the resistance reading. A normal diode should read infinite resistance in one direction and approximately 50 KQ or less when the meter leads are reversed. Note: Meters opera ted with less than 6 V battery are not adequate tor these checks. The meter should be first checked with a diode known to be good before judging a diode to be defective. Safety switches check Disconnect the oven, remove wire from terminal 1 of the switch, connect an ohmmeter to the terminals 1 and 4. With closed dOOf reading should be short circuit, with open door reading must be infinite. If reading is short circuit or infinite all the time, the switch must be replaced. 1 'I ~
)
I)
~
~
~ ~ ~
n
Note: If a safety switch is replaced make sure it is activated when the door is closed.
n
~
I
'
4
Failure monitor switch check
Fig. 16
2
~.o!
1
Disconnect the oven, remove one wire tram the switch, connect an ohmmeter to the terminals of the switch. With open door reading has to be short circuit, with closed door reading has to be infinite. If reading is short circuit or infinite all the time switch must be replaced. Note: When replacing the failure monitor switch make sure the switch is activated when the door is open.
~
')
~
~ ~
,~
j
.I
i
"
)
'\
"
/'"'"'\ ,
1-"""\
)
..,
~
'l
)
:,? ,;;;;'1 :: t):;: \
\
Ed. 01 -May 91
~
, !
\
'\
i
|
|
|
> |
|