|
Who's Online
There currently are 5593 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
High quality scan of service manual. I am satisfied!
;
Excellent copies.
I will use "Owner Manual" again a second time.
;
Very good manual for Technics SL 303. Manuale molto utile.
;
About one hour after checkout, the manual was available for download. Clear reading and detailed. Thanks
;
Excellent transaction - clean document received - Thanks a lot
2-3
SERVICE TEST PROGRAM
1. PRELIMINARY SETUP � To enter the service test program hold the keys �PROGRAM� and �STOP� depressed while turning POWER ON. � The display shows the software-version of the built-in microprocessor (e.g. �90S�). � The program is now in the main menu � various tests can be entered by pressing the corresponding buttons (see flow chart or detailed description of test programs below). 2. DISPLAY TEST Purpose: Check the internal display driver of the µP and the display segments. � To enter the display test start service test program and press the �NEXT� button. � The display shows test pattern 1. Three more test patterns are available. � To jump to the next pattern press the �PLAY� button. � To exit the display test and return to the main menu press the �STOP� button. 3. KEY & REMOTE CONTROL TEST Purpose: Check operation of keys and remote control. � To enter the key & remote control test start service test program and press the �MODE� button. � The display shows �--�. � Press keys on the set resp. the remote control and check the corresponding key codes on the display of the CD-player resp. the test patterns on the display of the remote control. Codes and patterns can be found in table 1 (see flow chart). � To exit the key & remote control test and return to the main menu press the �STOP� button. 4. PLAYBACK TEST WITH ERROR ANALYSIS Purpose: Analyse errors that occur during playback. � To enter the playback test start service test program and press the �DSP� button. Note that the playback test can only be entered if the CD-door is closed. � The set now reads the TOC and switches to stand-by. � Press the �PLAY� button to start the error analysis. As long as the playback is free of errors the display shows track and time information as in normal play-mode. In case of an error a corresponding error code will be displayed. The meaning of this error code can be found in table 2 (see flow chart). Note: Errors can either be �fatal� or �non fatal�. Fatal errors always stop the playback, non fatal errors only cause a short interruption of the music. Fatal errors are displayed as long as the set is connected to the power source, non fatal errors are displayed till a new error occurs or a button is pressed. � To stop the playback test disconnect the set from the power source.
6. SERVO TEST Purpose: Check door- and inner-switch, movement of slide and acceleration of discmotor. � To enter the servo test start service test program and press the �PLAY� button. � The display shows �S xy�. �x� indicates state of door-switch; �y� indicates state of inner-switch. x,y = �1� means switch is open. � To move slide outside hold the �NEXT� button depressed. � To move slide inside hold the �PREV� button depressed. � To accelerate the discmotor clockwise hold the �MODE� button depressed. � To accelerate the discmotor counter-clockwise hold the �DSP� button depressed. � To enter the focus test press the �PLAY� button, to exit the servo test and return to the main menu press the �STOP� button. 7. FOCUS TEST Purpose: Check movement of lens and operation of focus servo. � The focus servo loop is switched on and the set starts searching the focus. If the focus is OK the display shows � F�, else �-F�. � When the disc is turned manually �focus noise� is audible. � To move slide outside hold the �NEXT� button depressed. � To move slide inside hold the �PREV� button depressed. � To accelerate the discmotor clockwise hold the �MODE� button depressed. � To accelerate the discmotor counter-clockwise hold the �DSP� button depressed. � In case the focus is OK the discmotor test can be entered by pressing the �PLAY� button, to exit the focus test and return to the main menu press the �STOP� button. 8. DISCMOTOR TEST Purpose: Check speed regulation of discmotor. � The speed regulation is switched on and the discmotor starts rotating. If the speed reaches 75% of the nom. speed the display shows � d�, else �-d�. Note: During this test the µP displays the speed-flag of the CD7. As this IC can only monitor a small range of speed deviation the displayed information is not very reliable. In case of doubt check disc motor control circuit. � In case the disc speed is OK the radial test can be entered by pressing the �PLAY� button, to exit the discmotor test and return to the main menu press the �STOP� button.
9. RADIAL TEST Purpose: Check if radial loop locks and an audio signal is output. � The display shows �rd�. � The radial servo loop is switched on, mute is released and an audio signal is audible. � To jump 10 tracks outside press the �NEXT� button. � To jump 10 tracks inside press the �PREV� button. � To enter the error correction analysis press the �PLAY� button, to exit the radial test and return to the main menu press the �STOP� button. 10. ERROR CORRECTION ANALYSIS Purpose: Check the error status of the CD7 in double speed mode (measurement of block error rate, number of interpolations, a.s.o). � The display shows �H�. � The disc turns at double speed, mute is released and music is audible with twice the normal speed. Note: This test program is used for statistical analysis of the error correction of the CD7. As the test requires additional hard- and software it can´t be carried out at �normal� repair shops. � To exit the error correction analysis and return to the main menu press the �STOP� button.
5. IC-CHECK Purpose: Check communication between µP � CD7 and µP � NPC (DRAM controller). � To enter the IC-check start service test program and press the �PLAY� button. � The display shows �Cx ny�. �Cx� indicates result of CD7-check; �ny� indicates result of NPC-check. x,y = �1� means that the test has been passed successfully; x,y = �0� specifies an error during communication. � To enter the servo test press the �PLAY� button, to exit the ICcheck and return to the main menu press the �STOP� button.
CS 46 434
|
|
|
> |
|