Categories
|
Information
|
Featured Product
|
|
|
 |
|
There are currently no product reviews.
 ;
The manual you sent me was excellent. It included clear, readable diagrams and a usable parts list. I would surely use your service again. Thanks
 ;
Payments were processed quickly and items were exactly as described. I will use owner-manuals.com in the future for any other manual needs.
 ;
The Technics manual was very clear and I was able to solve my technical problems.
I did not think that anyone kept these manuals and was pleasantly surprised to find them on the Internet and at an affordable price.
I would recommend Owner Manuals as a first source of technical products for ‘dated’ equipment manuals.
Ian
 ;
The content of the manual was not found on the Internet and was a hard find. I check the net for 5 hours until I came across this web-site. When I did find the book it Auto loaded into my IPAD PDF shelf for books for review at anytime. Overall I am satisfied with the book and it answered all my questions. This repair book is obsolete because the product I bout it for is pretty old. Thanks for the help with the download and even having the manual. Thanks 73's K5HRD
 ;
Excellent manual including schematics. The service was great and the manual helped complete the job.
2-3-3. 3.58 f0 Adjustment
Note 1: ON/OFF of ACC should be performed with BKM127W menu of MAINTENANCE menu. Note 2: The following adjustment menu is below the BKM-127W menu of the MAINTENANCE menu. F0 1. Turn OFF ACC. 2. Input the NTSC color bar signal. 3. Connect TP322 and TP321 (5V) of the BW board using a jumper wire. 4. Connect the oscilloscope to TP421 of the BW board. 5. Adjust the F0 data so that the waveform stops or moves slowly. 6. Turn ON ACC. 7. Disconnect the jumper wire.
2-3-4. Phase Adjustment
Note 1: ON/OFF of ACC should be performed with BKM127W menu of MAINTENANCE menu. Note 2: The following adjustment menus are below the BKM-127W menu of the MAINTENANCE menu. SUB PHASE ACC PHASE R�Y PHASE 1. Input the NTSC color bar signal whose R�Y signal has been turned off. 2. Turn OFF ACC. 3. Connect the oscilloscope to TP421 of the BW board. 4. Adjust the SUB PHASE data so that the TP421 waveform becomes flat. 5. Turn ON ACC. 6. Adjust the ACC PHASE data so that the TP421 waveform becomes flat. TP421
Below 10mV
Fig. 2-5. Fig. 2-4.
7. Input the NTSC color bar signal whose R�Y signal has been turned off. 8. Connect the oscilloscope to TP471 of the BW board. 9. Adjust the R�Y PHASE data so that the TP471 waveform becomes flat. TP471
H Period Below 10mV
Fig. 2-6.
2-4