Hi, thankyou for providing the Nordmende Globetrotter original manufacturer's repair manual. Quality is very good and sharp - the PDF file was comfortably small to download. The only question is: why did it take so long to become ready for download?? Many thanks anyway, I fixed the fault in the radio thanks to the circuit.
regards: Nick
 ;
This was super service.Ordered this manual and was reading the download an hour later
 ;
as always, rapid and efficient, very good and clear prints
details clearly visible keep going this way!!!!!!
 ;
I expect a wonderful result as alaways!!!!!!
Usually is much faster....
1-3. Switching Regulator Replacement 1-4. Fuse/IC Link Replacement
1-3. Switching Regulator Replacement
w Unplug the power supply cord before replacing the switching regulator. n Do not disassemble the switching regulator. 1. Remove the top plate. (Refer to Section 1-1-1.) 2. Raise the wiring clip. 3. Disconnect the connector (CN1). (Refer to Section 11-2.) 4. Remove the two screws (B3x8). 5. Remove the screw (BVTP3x10). 6. Remove the four screws fixing the connectors. 7. Remove the three screws (PSW3x6), then remove the CPU-321/CPU-323 board. 8. Remove the five solders fixing the switching regulator. 9. Remove the switching regulator from the CPU-321/ CPU-323 board.
Switching regulator CPU-321 /CPU-323 board PSW 3x6 Wiring clip PSW 3x6
1-4. Fuse/IC Link Replacement
w A fuse and an IC link is critical parts to safe operation. Replace this component with SONY parts whose part numbers appear in this manual published by SONY. If not, this may cause a fire or electric shock. Be sure to use specified component in this manual. The BKS-R3216/R1617/R1618/R3219/R3220/R1621/ R3240A/R3242A/R3248A has a fuse and an IC link for circuit protection. A fuse and an IC link will blow when abnormality occurs and an overcurrent flows in this equipment. Be sure to replace an old fuse and an IC link with the specified fuse or IC link as shown below after removing the foreign substances that may cause the shorts.
Board CPU-321 CPU-323 IF-803 Ref. No. F1 (A-2) F1 (A-2) PS1 (C-2) PS1 (A-2) Part name H.B.C fuse 2A, 250V H.B.C fuse 2A, 250V IC link, Chip 2A IC link, Chip 0.52A Part No. !1-576-228-11 !1-576-228-11 !1-533-282-21 !1-533-539-11
NOTE: The character in parentheses ( ) indicate the address on board.
Washer
Connector screws BVTP 3x10 B 3x8
n On installing the switching regulator, install it in the reverse order of the removal steps 1 to 9.
1-6 (E)
BKS-R3216/R1617/R1618 BKS-R3219/R3220/R1621 BKS-R3240A/R3242A/R3248A
|
|
 |
> |
|