CHAPTER 5 TROUBLESHOOTING
Test Paper Feed A test paper feed starts when the DIP switches are set as follows, and the power is turned on: SW201-1: ON, SW201-2: OFF, SW201-3: ON, SW201-4: OFF. This test continues as long as there is paper in the cassette. The paper feed mode is exited by turning off SW201-1 and the test paper feed is interrupted. The test paper feed can be resumed by setting SW201-1 back to ON again.
Caution:
3.
1. Since the printer assembly is not on when the unit is in the paper feed mode, fed paper and delivered sheets will cause a paper jam in the printer assembly. Thus, if multiple sheets are loaded in a cassette in the paper feed mode when the unit is installed in the printer assembly, paper will be continuously fed to the printer assembly, causing repeated jams. For this reason, place only one paper sheet in the cassette. 2. When tests in the paper feed mode are completed, turn off all DIP switches.
COPYRIGHT © 1999 CANON INC.
CANON 2 � 500 SHEET PAPER DECK-C1 REV.0 FEB. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)