Who's Online
There currently are 5720 guests and 20 members online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Thank´s for your help, I already recived these manual from you
;
Thank you for your manual It has the basic things to and i use the Oszi for Longer Time.
THX
;
Actually, I was looking for this information for 3 years!...now thanks to you, the manual is on my hands and of great help, cause I understand now where I was doing wrong connections and wires...excellent, I'll be back to you if in need, thank you.
;
This manual covers the main equipment features only. While it also includes the procedure for saving and loading from the now long obsolete memory cards it does not mention the how to operate with the optional floppy drive interface so I am still at a loss about how to use this! Note that there is a separate manual covering the MIDI interface and programming via the keyboard, not included in this download. You will also need to get hold of this if you want to use the MIDI interface properly. Basically there is little difference between this manual and the free to download manual for the similar PR60 model.
;
Good list of manuals. I found a very rare one and easily get. Should be promptly to download, as we must to wait hours even after confirmed payment.
CCB-M series
SPECIFICATIONS
Durability
Item Vibration Conditions Only endurance conditioning by a frequency sweep shall be made. The entire frequency range, from 10Hz to 55Hz and return to 10Hz shall be transversed in 1 min with an amplitude (total excursion) of 1.5mm. This vibration shall be applied for a period of 2h in each of 3 mutually perpendicular axes (a total of 6h). Refer to IEC Pub. 68-2-6 for other procedures. Peak acceleration : 40G Duration of pulse : 6ms Three successive shocks shall be applied in both directions of 3 mutually perpendicular axes (a total of 18 shocks). Refer to IEC Pub. 68-2-27 for other procedures. The specimen shall be stored at a temperature of -25±3�C for 6h and then subjected to standard atmospheric conditions for 1h. After this procedure, measurements shall be made. Refer to IEC Pub. 68-2-1 Test Ab for other procedures. The specimen shall be stored at 85±2�C for 6h and then subjected to standard atmospheric conditions for 1h. After this procedure, measurements shall be made. Refer to IEC Pub. 68-2-1 Test Bb for other procedures. The specimen shall be stored at 40±2�C and a relative humidity of 90% to 95% for 96 +4h and then subjected to standard atmospheric conditions for 1h. After this procedure, measurements shall be mode. Refer to IEC Pub. 68-2-3 for other procedures. The specimen shall be subjected to 5 continuous cycles, each as shown in the table below. Following the final cycle, the specimen shall be stored at standard atmospheric condition for 1h, after which measurements shall be made. Temperature -25 ±3�C Standard atmospheric conditions 70 ±2�C Standard atmospheric conditions Duration 30 min. 10 to 15 min. 30 min. 10 to 15 min. Specifications No distinct looseness of terminals or visible deformation. Electrical characteristics shall be satisfied.
Shock
No distinct looseness of terminals or visible deformation. Electrical characteristics shall be satisfied.
Cold
No distinct looseness of terminals or visible deformation. Electrical characteristics shall be satisfied.
Dry heat
No distinct looseness of terminals or visible deformation. Electrical characteristics shall be satisfied.
Damp heat
No distinct looseness of terminals or visible deformation. Electrical characteristics shall be satisfied.
Change of temperature
No distinct looseness of terminals or visible deformation. Electrical characteristics shall be satisfied.
1 2 3 4
Refer to IEC Pub. 68-2-3 for other procedures. NOTE : This data is based on the board each. In assembled, the data on Shock, Vibration are to be changed according to the housing.