This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site.
Thank you very much
Text excerpt from page 43 (click to view)
7 Troubleshooting
7-2-7 Poor Focus
Adjust focus VR.
Improved focus?
Yes
Aging monitor and check for focus change.
No Check focus leads from FBT to CRT Socket.
Check the CRT Socket.
Is dynamic focus circuit right?
No
Refer to 7-1-15 Dynamic Focus Failure.
Yes Replace the CRT and verify focus.
7-2-8 Purity Failure
Degaussing
Purity is right?
Yes
Done
No Degaussing circuit is right? No Refer to 7-1-20 Degaussing Failure.