Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Excellent service manual includes everything is need to repair this radio-caseete, how to disassemble, wiring diagram, all , waiting time until the download was only a few hours. I'm going to buy service manuals from here, are cheap and very good.Thank you.
;
Good service manual,i saved from scrapping this deck,is now fully functional.Thanks.
;
Found this to be the manual included with the original packinging, was helpfull but did not give any detailed repair instructions.
;
Complete service manual, was very helpful in repairing this tapedeck.Thanks.
;
The service manual was a copy of the original from Wirlpool. The quality was good, all neccecary information was available including the service-codenumbers, so I could order the right part to be replaced for repair.
Downloding was no probem after the payment.
Thanks for the service!
CS-MC12DKK CU-2C24DKK
10.5. Indoor unit
10.5.1. SELECT THE BEST LOCATION (Refer to �Select the best location� section) 10.5.2. HOW TO FIX INSTALLATION PLATE
The mounting wall is strong and solid enough to prevent it from the vibration.
10.5.3. TO DRILL A HOLE IN THE WALL AND INSTALL A SLEEVE OF PIPING
1. Insert the piping sleeve to the hole. 2. Fix the bushing to the sleeve. 3. Cut the sleeve until it extrudes about 15 mm from the wall. Caution
When the wall is hollow, please be sure to use the sleeve for tube ass�y to prevent dangers caused by mice biting the connecting cable.
4. Finish by sealing the sleeve with putty or caulking compound at the final stage.
The wall must be able to withstand the weight of the unit. The centre of installation plate should be at more than 450 mm at right and left of the wall. The distance from installation plate edge to ceiling should more than 67 mm. From installation plate left edge to unit�s left side is 74 mm. From installation plate right edge to unit�s right is 94 mm.
: For left side piping, piping connection for liquid should be about 15 mm from this line. : For left side piping, piping connection for gas should be about 45 mm from this line. : For left side piping, piping connecting cable should be about 800 mm from this line.
10.5.4. INDOOR UNIT INSTALLATION
1. For the right rear piping
1. Mount the installation plate on the wall with 5 screws or more. (If mounting the unit on the concrete wall consider using anchor bolts.) � Always mount the installation plate horizontally by aligning the marking-off line with the thread and using a level gauge. 2. For the embedded piping 2. Drill the piping plate hole with ø 70 mm hole-core drill. � Line according to the left and right side of the installation plate. The meeting point of the extended line is the centre of the hole. Another method is by putting measuring tape at position as shown in the diagram above. The hole centre is obtained by measuring the distance namely 150 mm and 125 mm for left and right hole respectively. � Drill the piping hole at either the right or the left and the hole should be slightly slanted to the outdoor side.