DISASSEMBLY INSTRUCTIONS
4. Insert one end of the Anode Support into the anode button, then the other as shown in Fig. 1-5.
CRT
Support Fig. 1-5
5. Confirm that the Support is securely connected. 6. Put on the Rubber Cap without moving any parts.
2. REMOVAL OF DEFLECTION YOKE
(Refer to Fig. 2-1) 1. Loosen the screw 1. 2. Remove the Convergence � Purity Magnet in the direction of arrow (A). 3. Loosen the screw 2. 4. Remove the 3 Wedges. 5. Remove the Deflection Yoke in the direction of arrow (B).
2 Wedge (B) (A) 1
Convergence � Purity Magnet Deflection Yoke Wedge Fig. 2-1 INSTALLATION Install new Deflection Yoke in reverse steps of REMOVAL. NOTE After adjusting the purity and the convergence, fix the screw 2 and lock the wedges.