1. SERVICE NOTE
1-1. NOTE FOR REPAIR
Make sure that the flat cable and flexible board are not cracked of bent at the terminal. Do not insert the cable insufficiently nor crookedly. When remove a connector, don�t pull at wire of connector. It is possible that a wire is snapped.
When installing a connector, don�t press down at wire of connector. It is possible that a wire is snapped.
Cut and remove the part of gilt which comes off at the point. (Be careful or some pieces of gilt may be left inside)
1-2. POWER SUPPLY DURING REPAIRS
In this unit, about 10 seconds after power is supplied to the battery terminal using the regulated power supply (8.4V), the power is shut off so that the unit cannot operate. These following method is available to prevent this. Method: Use the AC power adaptor (AC-L25A/L25B).
DCR-HC17E/HC19E/HC21/HC21E/HC22E/HC32/HC32E/HC33/HC33E
1-1
|
|
 |
> |
|