Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
;
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site.
Thank you very much
SERVICE NOTE
1. POWER SUPPLY DURING REPAIRS
Battery switch
In this unit, about 10 seconds after power is supplied (8.4V) to the battery terminal using the service power cord (J-6082-223-A), the power is shut off so that the unit cannot operate. This following three methods are available to prevent this. Take note of which to use during repairs.
Method 1.
Connect the servicing remote commander RM-95 (J-6082-053-B) to the LANC jack, and set the remote commander switch to the �ADJ� side.
Method 2.
Press the battery switch of the battery terminal using adhesive tape, etc.
Method 3.
Use the DC IN terminal. (Use the AC power adaptor.)
Battery terminal � DC IN terminal Battery terminal �
Battery SIG terminal
2.
1 2 3 4 5 6
TO TAKE OUT A CASSETTE WHEN NOT EJECT (FORCE EJECT)
Refer to 2-2. to remove the front panel assembly. Refer to 2-2. to remove the cabinet (R) assembly. Refer to 2-5. to remove the battery panel assembly. Refer to 2-5. to remove the cabinet (L) assembly. Disconnect CN901 of VC-213 board. Add +5V from the DC POWER SUPPLY and unload with a pressing the cassette lid.
7 Pull the timing belt in the direction of arrow A with a pincette while pressing the cassette lid (take care not to damage) to adjust the bending of a tape.
Press the cassette lid to rise the cassette compartment
Pincette Timing belt [DC power supply] (+5V)
8 Let go your hold the cassette lid and rise the cassette compartment to take out a cassette.
Loading motor
Disconnect CN901 of VC-213 board. Timing belt Adjust the bending of a tape