2. Installation
(1) Using desoldering braid, remove the solder from the foil of each pin of the flat pack-IC on the CBA so you can install a replacement flat pack-IC more easily. (2) The �I� mark on the flat pack-IC indicates pin 1. (See Fig. S-1-7.) Be sure this mark matches the 1 on the PCB when positioning for installation. Then presolder the four corners of the flat pack-IC. (See Fig. S-1-8.) (3) Solder all pins of the flat pack-IC. Be sure that none of the pins have solder bridges.
Example :
Instructions for Handling Semi-conductors
Electrostatic breakdown of the semi-conductors may occur due to a potential difference caused by electrostatic charge during unpacking or repair work.
1. Ground for Human Body
Be sure to wear a grounding band (1M�) that is properly grounded to remove any static electricity that may be charged on the body.
2. Ground for Workbench
(1) Be sure to place a conductive sheet or copper plate with proper grounding (1M�) on the workbench or other surface, where the semi-conductors are to be placed. Because the static electricity charge on clothing will not escape through the body grounding band, be careful to avoid contacting semi-conductors with your clothing. < Incorrect >
Pin 1 of the Flat Pack-IC is indicated by a " " mark.