Who's Online
There currently are 5803 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Great and quick support. The maual was exactly what I was looking for and my problem
solved. Many thanks.
;
Very good service Within one day i received a pdf of the users manual and electric circuits so I was able to measure the different voltages in the printed circuit and find out the fault Payment was also reliable and easy.Without the manual i could not have repaired.So thanks to "Search for a manual"
;
you are doing great job guys.....my father ask me to find out the schematics of Sony KV25R1D to sort out the problem ..(he was electrical technician, and excperianced with TV and simillar stuff). finally he found the cause and change all necessary parts....now he has got working old dog..and is very happy!!... thank you all.. NB..he also saved the repair cost.
;
Perfect. Received my manual within 24 hours. Clear scan of the manual I needed. No problem.
;
Item as described, very well detailed manual with complete schematics. I've received the download information shortly after payment, very good support.
1
2
3
4
1.3.8 Coefficient display of adjustment results
For some of the adjustments (FE and RF offset, FZD cancel, F and T gains, and RFAGC), the adjustment results can be displayed and confirmed in the test mode. The coefficient display in each auto adjustment is as follows: 1) FE and RF offset Reference value = 32 (coefficient of 32 indicates that no adjustment is required) The value is displayed in the unit of approximately 32 mV. Ex. When the FE offset coefficient is 35, 35 - 32 = 3 x 32 mV = 96 mV The correction is about +96 mV, which means the FE offset before adjustment is - 96 mV. 2) F and T gain adjustment Reference value for focus and tracking = 20
B
A
The displayed coefficient / the reference value indicates the adjusted gain. Ex. When the AGC coefficient is 40, adjustment of 40 / 20 = 2 times (+ 6 dB) has been performed. (It means that the original loop gain was half the target, and the whole gain was doubled to obtain the target value.) 3) RF level adjustment (RFAGC) Reference value = 8 The coefficient of 9 to 15 indicates to increase the RF level (for more gains). The coefficient of 7 to 10 indicates to decrease the RF level
C
(for less gains). When the coefficient changes by 1, the gain changes by 0.7 to 1 dB. When the coefficient is 15, the gain is the maximum at TYP + 7.9 dB. When the coefficient is 0, the gain is the minimum at TYP - 4.6 dB.
D
E
F
16
CX-3195
1 2 3 4
|
|
|
> |
|