Excellent quality on these manuals. Same as having the original printed manual and incredibly useful when doing a custom install like me. Keep it up on the good work.
5 stars on this manual since it is the complete version, not the half manual you find free for download all over the web. Good job.
Text excerpt from page 76 (click to view)
1
2
3
4
6.5 FREQUENCY CHECK FOR CLOCK
A
- PCL output
In the normal operation mode (with the detachable panel installed, the ACC switched ON, the standby mode cancelled), shift the TESTIN (Pin 86) terminal to H. The clock signal is output from the PCL terminal (Pin 37). The frequency of the clock signal is 312.5kHz that is one 32th of the fundamental frequency. The clock signal should be 312.5kHz. If the clock signal is out of the range, the X'tal (X601) should be replaced with new one.