9 ADJUSTMENT PROCEDURES
Although the repair of Main C.B.A. is separated, it needs the electrical adjustment and factory setting when it is replaced the Main C.B.A., IC6002 (Flash-ROM) and related parts. The electrical adjustment in this unit is separated two types as shown below. (Concerning to the adjustment conditions and procedures, please use the �Adjustment Manual� contained in �View 3� on the website. 1. Main unit adjustment: All adjustments except for LCD and EVF adjustments. This unit mounts the adjustment software for main unit, it wouldn�t need the connection between the PC and this unit with USB cable. 2. LCD and EVF adjustment: Adjustments for LCD and EVF. It need the connection between the PC and this unit with USB cable. (This adjustments needs the adjustment software contained in �View 3�. The connection is shown to the figure below.