3.4.2.
INITIAL SETTINGS:
When you replace the Main PCB, be sure to perform the initial settings after achieving the adjustment by ordering the following procedure in accordance with model suffix of the unit. 1. IMPORTANT NOTICE: Before proceeding Initial settings, be sure to read the following CAUTIONS.
2. PROCEDURES: � Precautions: Proceed the picture back up from the unit. (Refer to above "CAUTION 2") � Preparation. Set the Mode dial to "P" (Program AE mode). Set the [REC]/[PLAYBACK] selector switch to "[REC] (Red camera mark)". � Step 1. The temporary cancellation of initial setting: Set the [REC]/[PLAYBACK] selector switch to �[ REC ] (Red camera mark)�. While keep pressing [ E.ZOOM ] and �[ UP ] of Cursor buttons� simultaneously, turn the Power on. � Step 2. The cancellation of initial setting: Set the [REC]/[PLAYBACK] selector switch to �[ PALYBACK ]�. Press [ E.ZOOM ] and �[ UP ] of Cursor buttons� simultaneously, then turn the Power off. � Step 3. Turn the Power on: Set the [REC]/[PLAYBACK] selector switch to �[ REC ] (Red camera mark)�, and then turn the Power on. � Step 4. Display the INITIAL SETTING: While keep pressing [ MENU ] and �[ RIGHT ] of Cursor buttons� simultaneously, turn the Power off.