Who's Online
There currently are 5918 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
This is a great site. I placed my order and by the next am it was available for download. Had some problems with some missing copy on some pages. Once I brought the error to the OMC's attention, the issue was resolved. I'll come back again.
;
Mi spiace per non poter scrivere in inglese... ma sono veramente soddisfatto del servizio offerto. Grazie..!!
;
The quality of this manual is good. It has all schematics and setup information for both the MDS-B3 and the MDS-B4. The scan quality is quite good, all pages are readable, This service manual also contains scans of the operating instructions from the User manual.
;
Quick site processing. A complete and very useful manual with all details. Thank you!
;
Das Service Manual war von der ersten bis zur letzten Seite sehr informativ und hilfreich. Die Darstellung aller Teile war klar und der Text gut lesbar.
Vielen Dank, das war nicht der letzte Download bei ownner-manuals.com.
4-1-3. Video Tracking Check and Adjustment
(4) Turn the height adjustment nut of TG-3 counterclockwise by one to two turns so that the tape does not in contact with the upper flange of TG-3. (5) Turn the height adjustment nut of TG-4 clockwise so that the tape does not in contact with the lower flange of TG-4. (6) Turn the zenith adjustment screw of the AT head so that the right portion of the RF envelope waveform makes 50% to 100% of the maximum output level. (Fig. 1) At this time, check that the tape does not in contact with both upper flange of TG-3 and lower flange of TG-4. If the tape contacts either flange, repeat step (4) or (5). If the tape moves upward or downward following the guide flange movement, perform the following adjustment. This trouble cause is uneven tape tension at upside or downside of the tape caused by AT head zenith. . If the tape moves upward at TG-3: Turn the zenith adjustment screw counterclockwise. . If the tape moves downward at TG-4: Turn the zenith adjustment screw clockwise. (7) Turn the height adjustment nut of TG-3 so that the tape is in contacts with the upper flange and the RF envelope waveform becomes flat. (Fig. 2) At this time, the tape does not in contact with the lower flange of TG-4. If the waveform does not become flat, perform the check and adjustment below. 1 Clean the drum lead with a bamboo stick. (Refer to Section 5-2-4 of the maintenance manual part 1.) 2 Press down the tape by bamboo stick very lightly and check that the tape is running without aparting from the drum lead. 3 If the waveform does not become flat even though steps 1 and 2 mentioned above are performed, adjust the height of TG-3 so that the RF envelope waveform is nearly flat within the range of the specification 12 shown in the Fig.3. At this time, do not overpress the tape at TG-3. � Continued on the next page. �
Marker
TG-4
AT head
TG-3
. Alignment tape : SR2-1/SR2-1P (00:00 to 15:00)
AT head
Zenith adjustment screw
. Alignment tape : SR2-1/SR2-1P (00:00 to 15:00) (Tracking VR : Effective) : D112/SS-83 board lights up <Fig. 1> RF max
80%
50% ~100% Marker
<Fig. 2> Be flat If the pressure against the tape at TG-3 is too much, the waveform becomes as shown in the right figure. (NG)
4-24
DNW-A65/A65P
|
|
|
> |
|