1-6. PROCESS AFTER FIXING FLASH ERROR
When �FLASH error� (Self-diagnosis Code E : 91 : ** ) occurs, to prevent any abnormal situation caused by high voltage, setting of the flash is changed automatically to disabling charge and flash setting. After fixing, this setting needs to be deactivated. Flash error code can be initialized by the operations on the Setup screen.
Method for Initializing the Flash Error Code
Initialize
Initializes the setting to the default setting.
OK Cancel
See the following procedure. Cancels the resetting.
1 Select [OK] with v on the control button, then press z. The message �Initialize all settings Ready?� appears. 2 Select [OK] with v, then press z. The settings are reset to the default setting.
� Make sure that the power is not disconnected during resetting.