I had been looking everywhere for a proper service manual for this VCR. Everywhere else that has this available for download has a very light version. This is the full service manual with all aspects that would interest anyone looking for the service manual for the AIWA HV-MX100 Worldwide VHS VCR. Great quality (as always). A winner hands down. Best Quality.
;
Top quality manual. Covers all aspects you'd expect in a top quality service manual for this Panasonic VHS VCR. The manual resolution is high. Another top quality manual from the only site worth downloading manuals from! If you're looking for a manual for the PV-9662 VHS VCR, this is the one you'll want to get!
;
complete part-lists and pcb layout, schematic diagram is good enlargable,
;
Excellent, fast delivery, excellent product. Good luck!
;
This manual is for the usa model only. But it is clear
, accurate and comprehensive, including board layouts and schematics.
I found it extremely useful for my mitsubishi dp-86da, but the same diagram would also work for the realistic lab5000 and hi fi 80. Thanks.
5. PICTURE ADJUSTMENTS
5-1. SUB-BRIGHTNESS ADJUSTMENT 1) Pattern : PAL B/G Retma 2) Press the key to set the "STANDARD" mode. 3) Choose the "DP" using the � UP� � DOWN�keys. PR , PR 4) Check the Color 34step, the Tint 32step. 5) Maximize the Contrast. 6) Adjust the Brightness so that the second line of top appears , as follow.
2nd line
5-2. PIP SUB VIDEO LEVEL ADJUSTMENT 1) Pattern : PAL B/G Color Bar 2) Press the � S11�key of Service Remocon to set the "2-Picture" mode. 3) Press the � SERVICE�key of Service Remocon to cancel the "MENU" mode. 4) Connect the probe of Oscilloscope to PP01 of "Sub Video out". 5) Turn the RP14 of PIP PCB to make the voltage to be 1Vp-p. 6) Press the � S11�key of Service Remocon twice to cancel the "2-Picture" mode. 5-3. PIP Y, U, V LEVEL ADJUSTMENT" 1) Pattern : PAL B/G Color Bar 2) Press the � S11�key of Service Remocon to set "2-Picture" mode. 3) Press the � SERVICE�key of Service Remocon to cancel the "MENU" mode. 4) Connect the probe of Oscilloscope to "Y out" of PP02. 5) Adjust the RP11 to make the voltage of Main Y coincide with the Sub Y. 6) Connect the probe of Oscilloscope to of "U out" of PP02. 7) Adjust the RP13 to make the voltage of Main U coincide with the Sub U. 8) Connect the probe of Oscillocope to "V out" of PP02. 9) Adjust the RP12 to make the voltage of Main V coincide with the Sub V. 10) Press the � S11�key of Service Remocon twice to cancel the "2-Picture" mode.