Probably it never existed a 1081 official service manual from Commodore, it's look more like a NAPCEC service manual & diagrams compilation of the 1084 series and his variants, like the nap6523, 8cm505, 1084S, 1084P and obviously the 1081. It's more complete than other scans and the quality of the scans also are far superior. It has two circuit diagrams variants of the 1081, mono and stereo versions. It doesn't include a diagram for the Philips CM8500 or CM8501, they look like the 1081 but they are slightly different.
;
Rapid, clear well done as all the scheme I downloaded from this site. Great job very functional and very useful
10-2. CONVERGENCE ADJUSTMENTS
B. CIRCUMFERENCE CONVERGENCE ADJUSTMENT
NOTE : Before attempting any purity adjustments, the
receiver should be operated for at least 15 minutes. A. CENTER CONVERGENCE ADJUSTMENT 1) Receive crosshatch pattern with a crosshatch signal generator. 2) Adjust the BRIGHTNESS and CONTRAST Controls for a good picture. 3) Adjust two tabs of the 4-Pole Magnets to change the angle between them (See Fig. 3) and superimpose red and blue vertical lines in the center area of the picture screen. (See Fig. 4) 4) Turn both tabs at the same time keeping their angles constant to superimpose red and blue horizontal lines at the center of the screen. (See Fig. 4) 5) Adjust two tabs of 6-Pole Magnets to superimpose red/blue line with green on top of each other. Adjusting the angle affects the vertical lines and rotating both magnets affects the horizontal lines. 6) Repeat adjustments 3), 4), 5) keeping in mind red, green and blue movement, because 4-Pole Magnets and 6-Pole Magnets interact and make dot movement complex.
NOTE : This adjustment requires Rubber Wedge Kit.
1) Loosen the clamping screw on deflection yoke to allow the yoke to tilt. 2) Place a wedge as shown in figure 2 temporarily. (Do not remove cover paper on adhesive part of the wedge.) 3) Tilt front of the deflection yoke up or down to obtain better convergence in circumference. (See Fig. 4) Push the mounting wedge into the space between picture and the yoke to hold the yoke temporarily. 4) Place other wedge into bottom space and remove the cover paper to stick. 5) Tilt front of the yoke right or left to obtain better convergence in cicumference. (See Fig. 4) 6) Hold the yoke position and put another wedge in either upper space. Remove cover paper and stick the wedge on picture tube to hold the yoke. 7) Detach the temporarily mounted wedge and put it in another upper space. Stick it on picture tube to fix the yoke. 8) After placing three wedges, re-check overall convergence. Tighten the screw firmly to hold the yoke tightly in place. 9) Stick 3 adhesive tapes on wedges as shown in figur32.
4-POLE MAGNETS PURITY MAGNETS 4DJUST THE ANGLE (VERTICAL LINES)
CONSTANT
CONVERGENCE MAGNET ASSEMBLY
Fig. 3
ROTATE TWO TABS AT THE SAME TIME (HORIZONTAL LINES)
ADJUSTMENT OF MAGNET
BLUE RED
RED/BLUE GRN
BGR B G R B G R BGR RGB R G B BGR
BLUE RED
RED/BLUE GRN
R G B
4-Pole Magnets Movement
6-Pole Magnets Movement Incline the Yoke up(or down) Incline the Yoke right(or left)
Center Convergence by Convergence Magnets
Circumference Convergence by DEF. Yoke
Fig. 4 Dot Movement Pattern
12
|
|
|
> |
|