Who's Online
There currently are 5768 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
It's a good manual, this one it's a scan from the original factory service manual, great quality 100% readeable. definetely it worths what I paid for.
;
A good manual! fast service and good qualityi for pdf document.
thanks!
;
Very helpful and complete manual. Maybe only one negative is schematics have sometimes unreadable name of the parts. But it's not a big problem.
;
Excellent high quality schematics brought my old Heidelberg back to life. Fast download at a reasonable price. Thanks.
;
This document is just what I was looking for, it´s very useful, it contains adjustment procedures for the final stage of the power amp and also
has a complete wiring diagram and description of the main semiconductors used in the design.
CYCLE TIMING CHART NOTES
Note 1: Pre-Wash Sense Interval Pressure switch contact closure at any time during this interval causes the cycle to jump to interval 37. Immediately. For the normal cycle, the heater is �off� during this interval. For the heavy and pots-n-pans cycles the heater is �on� during this interval. The power scour option changes this interval to a 16 minute heated wash interval for all 3 cycles (normal, heavy and pots-n-pans). If the water temperature reaches 140ºF or the thermostat closes. The heater is turned �off�. Time continues to elapse and all other output states remain the same until the prescribed interval time has elapsed. Note 2: Pre-Wash Thermal Hold This thermal hold is only executed during the heavy and pots-n-pans cycles. The thermal hold setpoint is 140ºF or thermostat contact closure and the default time is 25 minutes. Pressure switch contact closure at any time during this interval causes the cycle to jump to interval 37. Immediately. Note 3: Pre-Rinse Sense Interval Pressure switch contact closure at any time during this interval causes the cycle to jump to interval 31. Immediately. For the normal cycle, the heater is �off� during this interval. For the heavy and pots-n-pans cycles the heater is �on� during this interval. The power scour option changes this interval to a heated wash interval for the normal cycle. If the water temperature reaches 140ºF or the thermostat closes. The heater is turned �off�. Time continues to elapse and all output states remain the same until the prescribed interval time has elapsed. Note 4: Pre-Rinse Thermal Hold This thermal hold is only executed during the heavy and pots-n-pans cycles and only occurs if the pressure switch trips during the sense or thermal hold intervals of the pre-wash the thermal hold setpoint is 140ºF or thermostat contact closure and the default time is 20 minutes. Pressure switch contact closure at any time during this interval causes the cycle to jump to interval 31. Immediately. Note 5: Main Wash Thermal Hold This thermal hold is automatic for the pots-n-pans and heavy cycles (set point = 140ºF). For the normal cycle. This thermal hold is invoked by selecting the power scour or high temp wash options (Set Point = 140ºF) or as a result of the pressure switch tripping during the pre-wash (Set Point = 130ºF). For the low energy wash and quick wash cycles. This thermal hold is invoked by selecting the high temp wash option (Set Point = 140ºF). In all cases, the default time for this thermal hold is 20 minutes Note 6: Main Wash Recirculation Interval The power scour option increases the length of this interval to 10:00 for the pots-n-pans and heavy cycles. Note 7: Final Rinse Thermal Hold This thermal hold is automatic for all cycles except the china wash and rinse only cycles (Set Point = 140ºF). For the china wash cycle, this thermal hold only occurs if the pressure switch trips during the pre-rinse (Set Point = 130ºF). In all cases the default time is 25 minutes. If the sani rinse option is selected, then the set point for this thermal hold becomes 150ºF and the default time changes is 25 minutes. Note 8: Air Dry The default status for the dry period is heat dry �on�. Selecting the �air dry� option causes the heater to be turned �off� during this interval. Note 9: China Dry Interval When the china wash cycle is selected, the heater will be turned off during this interval. Note 10: Option LED�s When a valid option is active, then the LED for the option will be �on�. Note 11: Sani Complete LED When the �sani rinse� option has been selected and completed. A �sani complete� indicator is illuminated at the end of the cycle. During a cycle in which �sani rinse� has been selected, the target thermal hold temperature for the �sani rinse� option must be satisfied and maintained. If this condition is not satisfied (because the final rinse thermal hold default time elapsed or power to the dishwasher was lost at any time during the remainder of the cycle that follows due to a door opening or AC line failure) then the sani complete indicator will flash on and off at the end of the cycle. Opening the door or pressing any key will turn the indicator off in either case. Note 12: Motor Drain Phase Winding This output is only �on� when the motor is starting in the wash mode. When the control has determined that the motor has started, the wash phase winding will be turned �off�. Note 13: Motor Drain Phase Winding This output is only �on� when the motor is starting in the drain mode. When the control has determined that the motor has started. The drain phase winding will be turned �off�. Note 14: Diagnostic Sensor Input Test The soil sense pressure switch input is active during this interval. Pressure switch contact closure at any time during this interval causes the cycle to jump to the next interval. Immediately. Note 15: Diagnostic Thermal Hold The default status for this thermal hold is �on�. The thermal hold set point is 140ºF or thermostat contact closure and the default time is 60 minutes. After 60 minutes, the thermal hold is terminated and normal cycle timing resumes. The diagnostic test cycle advance function can also be used to terminate this thermal hold. Note 16: Cycle Complete A clean indicator will be on at the end of this cycle. Opening the door or pressing any key will turn the indicator off. Note 17: Diagnostics Cycle -- Thermostat/Thermistor Indicator The �clean� LED will turn on during the display test at the beginning of the cycle (interval 11) and again at the conclusion of the cycle (interval 2) regardless of what it detects on the thermistor input. The �clean� LED will be on in intervals 1 through 8 of the cycle whenever an �open� (resistance greater than 200K OHMS. +/- 50K OHMS) is detected on the thermistor input by the control. Consequently, if a normally open operating thermostat were to be installed on the thermistor input, the �clean� LED would be on throughout the cycle until the thermostat tripped (e.g., during the thermal hold); With a thermistor installed, the clean LED would only be on in intervals 10 and 0. Because the thermistor always has a resistance of between 50 K-OHMS and 8 K-OHMS under normal operating conditions.
Options Water Heat: Forces a thermal hold to occur in the main wash regardless of soil level. The set point for this thermal hold is 140ºF. This option is automatic with the potsn-pans and heavy cycles. It is not available on china wash or rinse only cycles. Sani Rinse: Raises the setpoint temperature of the thermal hold in the final rinse to approximately 65ºC/150ºF. This option is not available with china wash, quick wash & rinse only cycles. This option is only possible on models that use a thermistor. Air Dry: Opens the circuit to the heater element during the dry period of the cycle. This option is not available on quick wash or rinse only cycles (which have no dry period). Power Scour: Inserts additional heated wash time into the pots-n-pans, heavy and normal cycle pre-wash sequence (interval 39 becomes a 16 minute, thermostatically controlled, heated wash). Turns the heater on in interval 33 of the normal cycle pre-rinse, invokes a thermal hold in the main wash of the normal cycle and extends interval 23 to 10 minutes in the pots-n-pans and heavy cycles. This option is not available on low energy, china wash, quick wash or rinse only cycles.