Who's Online
There currently are 6042 guests and 1 member online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
very good manual, with detail and clarity in esquematic diagrams and waveforms .
;
Very quality copy of original service manual, which contains the circuit diagrams, PCB and lists of components, well as recommendation for calibration procedures of device, also everything else, that need for repair, tuning and use this oscilloscope.
All presented copies have high-resolution, so you can view all in detail.
This manual will very useful for simple owners and for repairers.
I recommend these manual, because myself is owner of Philips PM3216 and I need sometimes servicing these oscilloscope (principally calibrating).
Also, these document is an example of excellent design of technical documentation.
;
Excellent printing quality.
A complete and very usefull service manual with all details.
GREAT SERVICE AT VERY LOW PRICE!
A+++++++++++++++++++++++++
;
manual excelente completo , diagramas y esquemas bien presentados y buena calidad de imagen.
;
muy buen manual completo de buena calidad de impresion preciso y detallado , muy útil para la reparación.
DV-525
7.1.2 TROUBLE SHOOTING
� No Power ON � FL is not turned ON � FL indication is unusual
START � Blow out fuse of the primary side � Blow out micro-fuse on the POWER SUPPLY Assy. (Check the each voltage.) (KU, KC : P202, P204, P205, P201) (Others : P611, P211, P711) � FL controller IC (IC101) on the FLKY Assy is damaged.
Power ON
Turn on the power again after 2 - 3 minutes. � Check the following connections : POWER SUPPLY Assy - DVDM Assy DVDM Assy - FLKY Assy FLKY Assy - PWSB Assy � Check each voltage (EV+5V, SW+5V, SW+3.3V, +6V and +12V) (If above voltage are not supplied, check the micro-fuse.)
Is FL turn on ? Yes
No
Is the indication of FL normal ? Yes
No
FL indication is dark or flickers.
� Short or open the zenner diode on the POWER SUPPLY Assy. (KU, KC : D207) (Others : D513) � Check the values of R110 - R120 on the FLKY Assy. Refer to the section "7.1.3 ERROR CODE".
Indicates the error message
� Blow out micro-fuse on the POWER SUPPLY Assy. (KU, KC : P201) (Others : P711)
Is tray open ? Yes
No
� Check the connection between PICKUP Assy and DVDM Assy. (14P flexible cable) � Check the +6V power supply voltage (above micro fuse).
Do the video and sound come on ? Yes
No
Check the connection between AVJB Assy and DVDM Assy.
Indicate the error message. OK
Refer to the section "7.1.3 ERROR CODE".
56
|
|
|
> |
|