There are currently no product reviews.
 ;
PDF Contains
Technical Data, Mechanical data, Detailed Circuit diagram with components value, PCB layout. Actual PCBs Print. Component List, Spare parts code list and Input output detail. It cover LBB1211, LBB1212, LBB1213, LBB1216, LBB1217.
It is the actual Service Manual for SQ10
 ;
very good manual with clear electrical schemes. Very helpful to find wat was wrong inside my microwave.
 ;
Hi, thankyou for providing the Nordmende Globetrotter original manufacturer's repair manual. Quality is very good and sharp - the PDF file was comfortably small to download. The only question is: why did it take so long to become ready for download?? Many thanks anyway, I fixed the fault in the radio thanks to the circuit.
regards: Nick
 ;
This was super service.Ordered this manual and was reading the download an hour later
 ;
as always, rapid and efficient, very good and clear prints
details clearly visible keep going this way!!!!!!
DV-525
7.1.2 TROUBLE SHOOTING
� No Power ON � FL is not turned ON � FL indication is unusual
START � Blow out fuse of the primary side � Blow out micro-fuse on the POWER SUPPLY Assy. (Check the each voltage.) (KU, KC : P202, P204, P205, P201) (Others : P611, P211, P711) � FL controller IC (IC101) on the FLKY Assy is damaged.
Power ON
Turn on the power again after 2 - 3 minutes. � Check the following connections : POWER SUPPLY Assy - DVDM Assy DVDM Assy - FLKY Assy FLKY Assy - PWSB Assy � Check each voltage (EV+5V, SW+5V, SW+3.3V, +6V and +12V) (If above voltage are not supplied, check the micro-fuse.)
Is FL turn on ? Yes
No
Is the indication of FL normal ? Yes
No
FL indication is dark or flickers.
� Short or open the zenner diode on the POWER SUPPLY Assy. (KU, KC : D207) (Others : D513) � Check the values of R110 - R120 on the FLKY Assy. Refer to the section "7.1.3 ERROR CODE".
Indicates the error message
� Blow out micro-fuse on the POWER SUPPLY Assy. (KU, KC : P201) (Others : P711)
Is tray open ? Yes
No
� Check the connection between PICKUP Assy and DVDM Assy. (14P flexible cable) � Check the +6V power supply voltage (above micro fuse).
Do the video and sound come on ? Yes
No
Check the connection between AVJB Assy and DVDM Assy.
Indicate the error message. OK
Refer to the section "7.1.3 ERROR CODE".
56
|