DV-5700/DVF-R9050/R9050-S
ADJUSTMENT
No. ITEM INPUT SETTING OUTPUT SETTING ALIGNMENT POINT VR601 ALIGNMENT FOR Y-signal = 1000mV 30mV FIG. Connect the oscilloscope to 100% COLOR BAR DISC Y output with 75-ohms resistor. Output Mode: Interlace 100% COLOR BAR DISC Connect the oscilloscope to COMPOSIT output with 75ohms resistor.
1
Y,Cb,Cr LEVEL
FIG.1
2
Y LEVEL
VR600
COMPOSIT-signal = 1000mV FIG.2 30mV
You need the step 1and 2 before next step 3
3
CHROM LEVEL
Connect the oscilloscope to 100% COLOR BAR DISC COMPOSIT output with 75ohms resistor Connect the oscilloscope to 100% COLOR BAR DISC Y output with 75-ohms resistor. Output Mode: Progressive