9. Using torx driver (T2) (GGK1095) , In case of method 1: Turn the skew adjustment screw A slightly while monitoring RF waveform level in the oscilloscope and set the level to the maximum. At the middle periphery of pickup, turn the skew adjustment screw B slightly and set the level to the maximum. At the middle periphery of pickup, turn the skew adjustment screw A slightly again and set the level to the maximum. (Adjustments should be performed in the order of A, B, A, and please make sure each adjustment is completed as the screws turned to the right.) In case of method 2: Turn the skew adjustment screw A slightly while monitoring RF level in OSD and set the level to the maximum. At the middle periphery of pickup, turn the skew adjustment screw B slightly and set the level to the maximum. At the middle periphery of pickup, turn the skew adjustment screw A slightly again and set the level to the maximum. (Adjustments should be performed in the order of A, B, A, and please make sure each adjustment is completed as the screws turned to the right.)
A
B
B B A
A
C
[Criterion for Skew Adjustment OK] (DVD) Search inner periphery (ID: 40000) and outer periphery (ID: 200000), and respective error rate should be less than 1.000E - 3. If this is not satisfied, start over from step 9. (Disc used: GGV1025) Conduct a search after moving to the home position by CRG HOME, the error rate should be less than 2.500E - 3. If this is not satisfied, start over from step 9. (Disc used: TCD-782)
D
(CD)
* If the error rate does not fall within the abovementioned range by method 2, start over by method 1. 10. In FE Test Mode screen, after confirming the disc is stopped by Power OFF, eject the disc by Disc Eject.