Excellent quality on these manuals. Same as having the original printed manual and incredibly useful when doing a custom install like me. Keep it up on the good work.
5 stars on this manual since it is the complete version, not the half manual you find free for download all over the web. Good job.
Text excerpt from page 28 (click to view)
AV CBA Bottom View
CAUTION ! Switching power supply circuit is used in this unit. If Main Fuse (F1001) is blown, check to see that all components in the power supply circuit are not defective before you connect the AC plug to the AC power supply. Otherwise it may cause some components in the power supply circuit to fail.
NOTE : THE VOLTAGE FOR PARTS IN HOT CIRCUIT IS MEASURED USING HOT GND AS A COMMON TERMINAL. CAUTION FOR CONTINUED PROTECTION AGAINST FIRE HAZARD, REPLACE ONLY WITH THE SAME TYPE FUSE.
BECAUSE A HOT CHASSIS GROUND IS PRESENT IN THE POWER SUPPLY CIRCUIT, AN ISOLATION TRANSFORMER MUST BE USED. ALSO, IN ORDER TO HAVE THE ABILITY TO INCREASE THE INPUT SLOWLY, WHEN TROUBLESHOOTING THIS TYPE POWER SUPPLY CIRCUIT, A VARIABLE ISOLATION TRANSFORMER IS REQUIRED. NOTE : Either BE56A3F01015,BE56A3F01016 is used for the AV CBA in this S/M.
WF1 PIN 8 OF CN1601 WF2 PIN 10 OF CN1601 WF3 PIN 12 OF CN1601 WF4 PIN 16 OF CN1601 WF5 PIN 18 OF CN1601 WF6 PIN 21 OF CN1601