This GRUNDIG UV5A Owner Manual is not only an instruction manual but a total functional circuit description of the Multimeter and includes circuit diagram at the end pages. It is very helpful for repairing and calibrating the instrument. It is written in two languages English and German for international support. It was very easy to repair my unit with this document. Regards, Regis Pauly, Electrical Engineer.
The owner's manual was evetything I thought it would be. I was able to print it out using both sides of the paper in quick order, saving me a search online for a used one.
Fantastic quality and impressive delivery time. Based on this manual, I recommend this service without hesitation! Five Stars for certain.
Text excerpt from page 7 (click to view)
Installation
Important
This appliance must be installed by qualified personnel. The installer shall verify the satisfactory operation of the ignition system on all burners both individually and in combination. The manufacturer will not accept liability, should the above instructions or any of the other safety instructions incorporated in this book be ignored.
Regulations
This appliance shall be installed in accordance with the manufacturer�s installation instructions, local gas fitting regulations, municipal building codes, AS5601 (AG601) and any other relevant statutory regulations.
Data label
The data label is located on the bottom of the appliance. This appliance is suitable for Natural or Universal LPG. Ensure that the gas supply matches the data label. A duplicate of the data label is supplied in the packaging of the user manual and must be attached to readily accessible adjacent surfaces of the appliances.
FO 0814
A) End of shaft with nut B) Washer
FO 0264
Connection to the gas supply
Gas connection must be carried out in conformity with the regulations in force. The appliance leaves the factory tested and regulated for the type of gas indicated on the plate which is situated in the lower position near the gas connection tube. Ascertain that the type of gas with which the appliance will be supplied is the same as that indicated on the plate. If different carry out all the operations according to the indications cited in the paragraph �adaption to different types of gas�. For a maximum output and minimum consumption ascertain that the pressure of the gas used has the values indicated in the table of �burner characteristics�. The joint is mounted on the intake area of the pipe, fitted with a filleted nut G 1/2", between the sealing components. Screw the parts without forcing, turn the joint in the direction required and then tighten everything.
C) Elbow
Natural gas appliances must be fitted with a pressure regulator and be installed at the inlet connection. The gas pressure must then be set as a part of the commissioning procedures. For U-LPG the pressure adjustment is made via the regulator fitted at the domestic cylinder. The natural gas regulator and U-LPG pressure test point must be accessible with the appliance installed.
Important
Upon completion of installation, always check: l that all the joints are completely sealed by using a soapy solution, never a flame; l that the gas pressure has been regulated to 1.00kPa for Natural Gas and 2.75kPa for Universal-LPG. The pressure test point is located on the regulator. The pressure should be measured and adjusted with the Wok burner on high flame; that the automatic ignition system is operating l satisfactory on all burners, both individually and in that the burners operate correctly, are stable, without yellow tipping or excessive noise on high and low flame. Then demonstrate to the customer the appliance operation and leave these instructions.
l
Connection
Carry out the connection to the gas plant only by means of a rigid metallic pipe conforming to the regulations in force. This appliance is not suitable for connection with a hose assembly. The joint for the entry of gas into the appliance is threaded R 1/2" (male thread). Carry out the connection avoiding any type of stress on the appliance. It is important to install the elbow correctly, with the shoulder on the end of the thread, fitted to the hob connecting pipe. Failure to ensure the correct assembly will cause leakage of gas.