I purchased a vintage Sony mixer off eBay and within the hour was able to locate and purchase the manual for it.I mean really,where else can you find a manual for a product made in 1983!? It was easy to find and purchase/download the manual I needed.I will use this site again for other equipment I have! Great site!
manual de usuario perfecto y completo de buena calidad de impresion y muy detallado ideal !
Text excerpt from page 19 (click to view)
Commissioning
When the hob has been fully installed it will be necessary to check the minimum flame setting. To do this, follow the procedure below. - Turn the gas tap to the MAX position and ignite. - Set the gas tap to the MIN flame position then turn the control knob from MIN to MAX several times. If the flame is unstable or is extinguished follow the procedure below. Procedure:
Re-ignite the burner and set to MIN. Remove the control knob. You can find two different adjustment screw locations according to the gas tap (sse diagram). The "b" type has the adjustment screw located down the centre of th egas tap control shaft. The "c" type has the by pass screw located to the side of the gas tap itself. To adjust, use a thin bladed screwdriver and turn the adjustment screw until the flame is steady and does not extinguish, when the knob is turned from MIN to MAX. Repeat this procedure for all burners.
FO 1032
a) Minimum adjustment screw b) Tap
Pressure Testing
Remove left hand pan support and front left burner cap and crown. Fit manometer tube over the injector. Turn on the burner gas supply and ignite another burner supply. The pressure reading should be nominally 20mbar and must be between 17 mbar and 25mbar. Turn off the burner supplies.