|
Who's Online
There currently are 5841 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
This manual provided the necessary information to properly use the C-3 deck. The manual was an excellent reproduction and very clear.
;
Product was very good. Received quickly and complete
;
Although printing quality is not the best, the manual was very helpful in order to reactivate this ancient but still good electronic musical instrument.
;
as a first-time user and buyer from this site, i found the overall service outstanding!! this product is a godsend as, without it, i would never have been able to find my way around and use my machine as intended. i will certainly use this site again as required. many many thanx!!
;
This manual is exactly what I needed. This site always has every manual I need, and it is also much less expensive then most other sites. This is the only manual site I will use.
Precautions during Servicing
A. Parts identified by the ( # ) symbol are critical for safety. Replace only with part number specified. B. In addition to safety, other parts and assemblies are specified for conformance with regulations applying to spurious radiation. These must also be replaced only with specified replacements. Examples: RF converters, RF cables, noise blocking capacitors, and noise blocking filters, etc. C. Use specified internal wiring. Note especially: 1) Wires covered with PVC tubing 2) Double insulated wires 3) High voltage leads D. Use specified insulating materials for hazardous live parts. Note especially: 1) Insulation Tape 2) PVC tubing 3) Spacers 4) Insulators for transistors. E. When replacing AC primary side components (transformers, power cord, etc.), wrap ends of wires securely about the terminals before soldering. F. Observe that the wires do not contact heat producing parts (heatsinks, oxide metal film resistors, fusible resistors, etc.) G. Check that replaced wires do not contact sharp edged or pointed parts. H. When a power cord has been replaced, check that 5~6 kg of force in any direction will not loosen it. I. Also check areas surrounding repaired locations. J. Use care that foreign objects (screws, solder droplets, etc.) do not remain inside the set. K. Crimp type wire connector The power transformer uses crimp type connectors which connect the power cord and the primary side of the transformer. When replacing the transformer, follow these steps carefully and precisely to prevent shock hazards. Replacement procedure 1) Remove the old connector by cutting the wires at a point close to the connector. Important: Do not re-use a connector (discard it). 2) Strip about 15 mm of the insulation from the ends of the wires. If the wires are stranded, twist the strands to avoid frayed conductors.
3) Align the lengths of the wires to be connected. Insert the wires fully into the connector. 4) Use the crimping tool to crimp the metal sleeve at the center position. Be sure to crimp fully to the complete closure of the tool. L. When connecting or disconnecting the internal connectors, first, disconnect the AC plug from the AC supply outlet.
2-3
L6115IMP
|
|
|
> |
|