Very clear scan, I recommend it. Definitely a must have for any 3362 owner.
Alpine could have written a slightly more complete manual, though. It's already pretty huge, but the unit has so many functions, I feel some more explanation would have been better.
Yamaha's manual of their comparable YDSP-1 is a little better in my opinion.
Correct manual received and of good quality but the contents of the file for the Service Manual for the same monitor is for a 20" TV not the RGB Monitor.
Text excerpt from page 20 (click to view)
� Remove any objects from the pump impeller by rotating it.
Emergency emptying out
If the water is not discharged, proceed as follows to empty out the machine: � pull out the plug from the power socket; � close the water tap; � if necessary, wait until the water has cooled down; � open the pump door; � place a bowl on the floor and place the end of the emergency emptying hose into the bowl. Remove its cap. The water should drain by gravity into the bowl. Whe the bowl is full, put the cap back on the hose. Empty the bowl. Repeat the procedure until water stops flowing out; � clean the pump if necessary as previously described; � replace the emergency emptying hose in its seat after having plugged it; � screw the pump cover again and close the door.
� Put the cap back on the emergency emptying hose and place the latter back in its seat.
P1117
Frost precautions
If the machine is installed in a place where the temperature could drop below 0°C, proceed as follows: � Remove the plug from the socket. � Close the water tap and unscrew the water inlet hose from the tap. � Place the end of the emergency emptying hose and that of the inlet hose in a bowl placed on the floor and let water drain out. � Turn the programme selector dial to O. � Switch the machine OFF by depressing button . � Screw the water inlet hose back on and reposition the emergency emptying hose after having put the cap on again. By doing this, any water remaining in the machine is removed, avoiding the formation of ice and, consequently, breakage of the affected parts. When you use the machine again, make sure that the ambient temperature is above 0°C.
� Screw the pump cover fully in. � Close the pump door.
Water inlet filter
If you notice that the machine is taking longer to fill, check that the filter in the water inlet hose is not blocked. Turn off the water tap. Unscrew the hose from the tap. Clean the filter with a stiff brush. Screw the hose back onto the tap.
P1090
Important! Every time you drain the water through the emergency emptying hose you must pour 2 litres of water into the main wash compartment of the detergent drawer and then run the drain programme. This will activate the ECO VALVE device avoiding that part of the detergent remains unused at next washing.