Doubted for buy this manual as it is my first order here and at not have cover image, I assumed would haven't. However, within 24 hs, already possessed the link to download it. The manual are scanned correctly and have all what is needed. Includes adjustments and diagrams of all circuits. Very satisfied.
;
Really good quality, аll readable.! Wonderful work shop. I recommend to all!
;
Good quality service manual.The scheme is on A3 format and very readable.Thank you
;
Very good service-manual with clear electrical diagrams. Thanks you.
FR-N3X ADJUSTMENT PROCEDURES-9
CLOCK FREQUENCY ADJUSTMENT
1. Remove the top cover. 2. Connect the frequency counter to the Test point on CD & microprocessor PC board (NADG-7557) 3. While hold down CD STOP key, press STANDBY/ON key to set the test mode. (All segments on FL tube light on and scroll the character for FL tube test.) 4. Adjust the trimmer capacitor C705 on NADG-7557 so that the reading of frequency counter becomes 12.500MHz
100 Hz.
Frequency counter Test point
GND
Chassis ground
124,999,00
125,000,10 Hz
Top view
Screw driver
C705 Trimming capacitor